MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2019.05.026

Медицинская библиотека · American journal of ophthalmology · 2019

Prospective, Randomized, Contralateral Eye Comparison of Wavefront-Guided and Wavefront-Optimized Laser in Situ Keratomileusis.

Roe Joshua R, Manche Edward E

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare outcomes in wavefront-optimized (WFO) laser in situ keratomileusis (LASIK) to high-resolution wavefront-guided (WFG) LASIK.

DESIGN

Randomized, fellow eye controlled, clinical trial.

METHODS

A total of 200 eyes of 100 patients with myopia or compound myopic astigmatism undergoing bilateral LASIK between October 2015 and February 2017 underwent wavefront-optimized (WFO) LASIK in 1 eye and wavefront-guided (WFG) LASIK in the fellow eye. Each eye was evaluated for uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), contrast sensitivity, refractive error, and wavefront aberrometry. Outcome measurement primarily UDVA at 12 months. Secondary outcomes were safety, predictability, stability, refractive error, CDVA, contrast sensitivity, and higher-order aberrations at 12 months.

RESULTS

WFG LASIK had higher levels of supervision and better contrast sensitivity compared to WFO. Both types had excellent postoperative UDVA results, without a significant difference in either mean UDVA or frequency of achieving a specified UDVA, for example, 20/16 or better (all P > 0.05). The mean gain in lines of CDVA was significantly higher in the WFG than in the WFO group (0.80 ± 0.75 vs 0.62 ± 0.72, respectively; P = 0.04). The WFG cohort had significantly better contrast sensitivity for mean and frequency of achieving >20/40 for <5% low-contrast sensitivity (37.1%; 95% confidence interval [CI], 27.5-46.7 vs 24.7%; 95% CI, 16.2-33.3, respectively; P = 0.01) and >20/32 for <25% low-contrast sensitivity (10.3%; 95% CI, 4.3-16.4 vs 4%, respectively; 95% CI, 0.0-8.1, respectively; P = 0.04). The WFO group had a significantly higher frequency of <0.25 diopters (D) of refractive astigmatism at 12 months (82.5%; 95% CI, 75.0-90.0; vs 72.1%, respectively; 95% CI, 63.2-81.2; P = 0.02) but not <0.50 D (95.6%; 95% CI, 91.9-99.8; vs 96.9, respectively; 95% CI, 93.5-100; P = 0.61). The WFG group was significantly closer to emmetropia for both sphere and spherical equivalents at all time points. Trefoil was significantly lower in the WFG group and was also significantly lower than preoperative measurements.

CONCLUSIONS

Wavefront-optimized and high-resolution wavefront-guided LASIK achieve excellent visual outcomes. Nonetheless, treatments based on a high-resolution aberrometer appear to offer superior results in some regards.

Для цитирования: Roe Joshua R, Manche Edward E. Prospective, Randomized, Contralateral Eye Comparison of Wavefront-Guided and Wavefront-Optimized Laser in Situ Keratomileusis.. American journal of ophthalmology. 2019. DOI: 10.1016/j.ajo.2019.05.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.