Медицинская библиотека · Journal of cataract and refractive surgery · 2019

Application of Purkinje images for pinhole pupilloplasty and relevance to chord length mu.

Narang Priya, Holladay Jack, Agarwal Amar, Jaganathasamy Nagaraj, Kumar Dhivya Ashok, Sivagnanam Soundari

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the results of pinhole pupilloplasty in cases with high astigmatism and higher-order aberrations (HOAs).

SETTING

Dr. Agarwal's Eye Hospital & Research Centre, Chennai.

DESIGN

Case series.

METHODS

Pinhole pupilloplasty was performed based on the Purkinje 1 (P1) images formed from the light source of a Lumera surgical microscope; the images served as a reference marker for centration. A single-pass 4-throw technique was used to achieve a pinhole pupil. The preoperative and postoperative pupil diameter, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, simulated keratometry (K), and chord length mu (μ) were assessed, the latter using a Pentacam rotating Scheimpflug camera.

RESULTS

Pinhole pupilloplasty was performed in 8 eyes (8 patients). There was a statistically significant reduction in the mean horizontal and vertical pupil diameters and in the mean pupil diameter from preoperatively to postoperatively (both P < .001). Although the improvement in UDVA was statistically significant (P < .001), the change in CDVA was not. The mean simulated K and mean chord length μ values were significantly lower postoperatively (P = .024 and P < .001, respectively). The reduction in pupil size was more apparent than the reduction in chord length μ. The correlation between the change in chord length μ and the change in pupil size was not significant (r = -0.067, P = .874). The pupil was well centered on the P1 images. No major adverse events or complications occurred postoperatively.

CONCLUSION

Postoperative results showed a correlation between the improvement in visual acuity and the decrease in pupil size and chord length μ.

Для цитирования: Narang Priya, Holladay Jack, Agarwal Amar, Jaganathasamy Nagaraj, Kumar Dhivya Ashok, Sivagnanam Soundari. Application of Purkinje images for pinhole pupilloplasty and relevance to chord length mu.. Journal of cataract and refractive surgery. 2019. DOI: 10.1016/j.jcrs.2019.02.037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.