Медицинская библиотека · Investigative ophthalmology & visual science · 1995

Assessment of retinal-neural function before neodymium:YAG laser capsulotomy.

McGraw P V, Brosnahan D, Winn B, Whitaker D

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this study was to evaluate a clinical test of hyperacuity in the assessment of retinal-neural function in patients with posterior capsular opacification.

METHODS

Neodymium (Nd):YAG laser capsulotomy was performed on 39 subjects (mean age, 76.72 years +/- 10.41 years). Measurements of refractive error, logMAR acuity, and displacement threshold hyperacuity (DTH) were made before and 3 weeks after Nd:YAG therapy. The DTH task involved measurement of the smallest detectable displacement of an object relative to two stationary references. In addition, an independent fundus examination was performed before and after therapy to determine the presence of retinal disease. By ophthalmoscopic examination, a blind protocol was adopted for the classification of subjects as normal or as having retinal disease.

RESULTS

Preoperative measures of logMAR visual acuity were of no value in distinguishing between patients with retinal disease and normals (P > 0.1) and were a poor indicator of postoperative logMAR acuity (r2 = 0.2). Preoperative DTH could be used to distinguish patients with retinal disease from normals (P < 0.005) and were found to be correlated with measures of postoperative logMAR acuity (r2 = 0.4). Preoperative DTH correlated well with postoperative DTH (r2 = 0.7), which is consistent with its resistance to optical image degradation.

CONCLUSION

The results of this study indicate that DTH is of value in the presurgical assessment of visual function in patients with media opacification if adequate fundus examination is not possible.

Для цитирования: McGraw P V, Brosnahan D, Winn B, Whitaker D. Assessment of retinal-neural function before neodymium:YAG laser capsulotomy.. Investigative ophthalmology & visual science. 1995.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.