MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/a-0861-9601

Медицинская библиотека · Klinische Monatsblatter fur Augenheilkunde · 2019

A Simple, Inexpensive, and Precise Photographic Method for Intraoperative Toric IOL Alignment.

Gerding Heinrich, Somfai Gabor Mark, Langenegger Marco

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

It was the aim of this study to analyse the refractive outcome of toric intraocular lens (t-IOL) implantation guided by a newly developed method of photographic alignment.

MATERIAL AND

METHODS

Fourteen eyes of 10 patients (6 females, 4 males, age 63.4 ± 6.7 (40.6 - 68.0) years [mean ± 1 SD (range)]) were included in this retrospective study. All eyes received an Oculentis Tplus LS-313 (Oculentis, Berlin, Germany) t-IOL after standard phacoemusification (n = 4) or femtocataract laser-assisted surgery (n = 10). Image-guided t-IOL alignment included: (1) calculation of t-IOL parameters (combination of different biometric methods) and plotting a layout drawing of the target lens position, (2) capture of an anterior segment slit lamp photograph in the upright position, (3)  superposition of the photographs by the t-IOL target plot and a gradual scale, (4) drawing of marker lines on the photograph and removal of the IOL target coordinates, (5) transfer of the final image to a tablet PC, and (6) marking of the target axis at the corneal limbus with an ink pen in the surgical room.

RESULTS

Preoperative corneal astigmatism was 2.50 ± 0.97 (1.38 - 4.34) diopters (D) (mean ± 1 SD, range). In all eyes, intraoperative alignment could easily be performed using the photographic target layout. Surgical interventions and postoperative follow-up were without complications in all cases. Residual postoperative astigmatism was 0.16 ± 0.24 (0.00 - 0.75) D (p < 0.001 compared to preoperative astigmatism). In 64% of patients, residual subjective astigmatism was zero, in 93% ≤ 0.5 D, and in 100% ≤ 0.75 D. Postoperative uncorrected logMAR visual acuity (0.05 ± 0.07, range 0.00 - 0.20) and best-corrected visual acuity (0.03 ± 0.05, 0.00 - 0.10) were significantly better (each p < 0.001) than best-corrected preoperative visual acuity (0.21 ± 0.14, 0.00 - 0.49).

CONCLUSIONS

Results of this clinical series clearly indicate that the newly developed photographically guided technique of toric lens alignment leads to highly accurate postoperative results for astigmatic correction.

Для цитирования: Gerding Heinrich, Somfai Gabor Mark, Langenegger Marco. A Simple, Inexpensive, and Precise Photographic Method for Intraoperative Toric IOL Alignment.. Klinische Monatsblatter fur Augenheilkunde. 2019. DOI: 10.1055/a-0861-9601.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.