DOI 10.3928/1081597x-20190313-01
Functional Optical Zone and Centration Following SMILE and LASIK: A Prospective, Randomized, Contralateral Eye Study.
Аннотация
PURPOSE: To compare centration and functional optical zone (FOZ) after small incision lenticule extraction (SMILE) and femtosecond laser-assisted in situ keratomileusis (LASIK).
METHODS
In this prospective, randomized, single-masked, paired-eyed, clinical trial, 70 patients received SMILE in one eye and LASIK in the other eye for myopia and myopic astigmatism. FOZ was calculated using custom software on 3-month postoperative refractive power maps (Pentacam HR; Oculus Optikgeräte GmbH, Wetzlar, Germany). Programmed treatment area was defined as the total area of the programmed OZ plus the transition zone. Centration was evaluated by the linear distance between FOZ centroid and the pupil center and the corneal apex.
RESULTS
The average preoperative spherical equivalent (-5.38 ± 1.65 vs -5.45 ± 1.61 diopters [D]), postoperative spherical equivalent (0.05 ± 0.39 vs 0.06 ± 0.39 D), uncorrected distance visual acuity (0.01 ± 0.13 vs 0.00 ± 0.08 logMAR), and corrected distance visual acuity (-0.07 ± 0.10 vs -0.07 ± 0.10 logMAR) were comparable in SMILE- and LASIK-treated eyes of the 60 patients with complete datasets (P > .419). Postoperative increase in spherical aberration was lower in SMILE than in LASIK (0.08 ± 0.16 vs 0.17 ± 0.18 µm, P = .002). The FOZ area was significantly larger in SMILE than in LASIK (30.25 ± 3.60 vs 29.21 ± 3.72 mm2), despite the smaller programmed OZ diameter (6.48 ± 0.08 vs 6.52 ± 0.11 mm) and smaller programmed treatment area (33.87 ± 0.81 vs 46.30 ± 2.61 mm2, P < .037). Pupil centration (0.43 ± 0.21 vs 0.41 ± 0.22 mm) and apex centration (0.48 ± 0.24 vs 0.48 ± 0.22 mm) were comparable between SMILE and LASIK (P > .694).
CONCLUSIONS
SMILE created a larger FOZ than LASIK, despite the smaller programmed OZ. This may be due to a difference in the biomechanical response between the two procedures. Visual outcome and centration were comparable between SMILE and LASIK. [J Refract Surg. 2019;35(4):230-237.].
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.