MedElevator Войти в исследования
← Поиск публикаций

DOI 10.18240/ijo.2019.03.12

Медицинская библиотека · International journal of ophthalmology · 2019

Comparison of visual quality in cataract patients with low astigmatism after ART2 or ReSTOR intraocular lens implantation.

Hao Jing, Tan Liang-Zhang, Li Lin, Bu Shao-Chong, Ren Xin-Jun, Tian Fang, Zhang Hong

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To compare visual quality in cataract patients with low corneal astigmatism who underwent intraocular lens (IOL) implantation, and evaluate effects of low levels of astigmatism on visual outcomes in multifocal pseudophakic eyes.

METHODS

This retrospective review of clinical records comprised patients with preoperative regular corneal astigmatism of 0.75-1.0 diopters (D) with-the-rule or 0.5-0.75 D against-the-rule who had uneventful cataract surgery and AcrySof IQ ReSTOR Toric-2 IOL (ART2) or AcrySof IQ ReSTOR IOL (ReSTOR) implantation. Retrospective data collection included postoperative ART2 axis rotation, uncorrected astigmatism, uncorrected entire visual acuities, distance corrected entire visual acuities, average modulation transfer function (aMTF), Strehl ratio (SR), spectacle independence, and patient satisfaction between groups.

RESULTS

Mean ART2 axis rotation was 3.12°±0.70°. No secondary surgery was required to realign IOL axis. Residual astigmatism values were -0.18±0.07 D and -0.91±0.25 D in groups ART2 and ReSTOR (P<0.05). Three months postoperatively, the mean uncorrected distant, intermediate, and near visual acuities of group A were 0.01±0.05, 0.05±0.07, 0.02±0.07 logMAR, respectively; these were better than those of group R, which were 0.08±0.06, 0.15±0.12, and 0.09±0.08 logMAR, respectively (P<0.05). aMTF, SR, and spectacle independence rates were not significantly different. All patients were satisfied with postoperative results.

CONCLUSION

ART2 is more suitable than ReSTOR for cataract patients with regular corneal astigmatism 0.75-1.0 D with-the-rule or 0.5-0.75 D against-the-rule.

Для цитирования: Hao Jing, Tan Liang-Zhang, Li Lin, Bu Shao-Chong, Ren Xin-Jun, Tian Fang, Zhang Hong. Comparison of visual quality in cataract patients with low astigmatism after ART2 or ReSTOR intraocular lens implantation.. International journal of ophthalmology. 2019. DOI: 10.18240/ijo.2019.03.12.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.