OBJECTIVE

To determine the safe distance range of clear corneal incision (CCI) from the corneal limbus and how different CCI sites affect surgery efficacy and anterior segment parameters in patients undergoing phacoemulsification.

METHODS

This retrospective case-control study was conducted in 44 patients (44 eyes) undergoing phacoemulsification and IOL implantation. The patients were divided into two groups with CCI distances ranging from 1 mm to 1.5 mm (group A, n= 22) and from 0.5 mm to 1.0 mm (group B, n= 22). The visual acuity, surgically induced astigmatism (SIA), corneal aberration, and anterior segment parameters were analyzed.

RESULTS

Compared with the preoperative data, all the patients showed significant improvements in the postoperative uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), anterior chamber depth (ACD), and anterior chamber angle (ACA) after the surgery (P < 0.05). No significant differences were found between the two groups in postoperative UCVA, BCVA, SIA, total corneal aberration RMS, lower- and higher-order aberration RMS, spherical aberration (Z40), horizontal three leaf clover (Z33), vertical three leaf clover(Z3-3), horizontal coma(Z31), vertical coma(Z3-1), ACD, ACA, anterior chamber volume, or central corneal thickness (P>0.05).

CONCLUSIONS

Phacoemulsification is an effective therapy for cataract with a CCI distance range either of 1-1.5 mm or 0.5-1.0 mm. These two CCI distance ranges produce no significant differences in the visual quality following phacoemulsification, indicating that a CCI distance range of 0.5-1.5 mm can be safe for phacoemulsification.

Для цитирования: Wang Lijun, Yang Xiting, Zhang Yi, Liao Dingying, Zhao Lin, Wang Jianming. [Effect of different clear corneal incision sites on surgery efficacy and anterior segment parameters in patients undergoing phacoemulsification].. Nan fang yi ke da xue xue bao = Journal of Southern Medical University. 2018. DOI: 10.12122/j.issn.1673-4254.2018.12.15.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.