The impacts of the ganglionated plexus ablation sequence on the vagal response, heart rate, and blood pressure during cardioneuroablation.

Hu Feng, Zheng Lihui, Liu Shangyu, Shen Lishui, Liang Erpeng, Liu Limin, Wu Lingmin, Ding Ligang, Yao Yan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: Cardioneuroablation is an emerging and promising therapy to treat vasovagal syncope (VVS). The aim of this study was to assess the characteristics of vagal response (VR), heart rate (HR), and blood pressure (BP) during cardioneuroablation with different sequences of ganglionated plexus (GPs) catheter ablation and clarify the regulatory mechanism of cardiac GPs of the left atrium.

METHODS

A total of 28 patients with VVS who underwent cardioneuroablation were prospectively enrolled and randomly assigned to 2 groups according to the ablation order of GPs. Group A: Left superior GP (LSGP) - Left inferior GP (LIGP) - Right inferior GP (RIGP) - Right anterior GP (RAGP); Group B: RAGP - LSGP - LIGP - RIGP.

RESULTS

In Group A, the VR in LSGP, LIGP, RIGP, and RAGP during ablation was observed in 11 (78.6%), 5 (35.7%), 4 (28.6%) and 2 (14.3%) cases, respectively. In contrast, in Group B, the VR in RAGP, LSGP, LIGP, and RIGP was observed in 2 (14.3%), 1 (7.1%), 0 (0%) and 0 (0%) cases, respectively. BP reduction during procedure was observed eight times in Group A and once in Group B (P = 0.013). In both groups, the HR increased significantly during ablation of the RAGP (all P < 0.001).

CONCLUSION

The sequence of GPs ablation during cardioneuroablation affected the occurrence rate of VR and BP reduction during cardioneuroablation. The RAGP was a critical target to increase HR and inhibit VR and BP reduction during procedure, indicating that it may be a key GP in regulation of the cardiac vagal activity.

Для цитирования: Hu Feng, Zheng Lihui, Liu Shangyu, Shen Lishui, Liang Erpeng, Liu Limin, Wu Lingmin, Ding Ligang, Yao Yan. The impacts of the ganglionated plexus ablation sequence on the vagal response, heart rate, and blood pressure during cardioneuroablation.. Autonomic neuroscience : basic & clinical. 2021. DOI: 10.1016/j.autneu.2021.102812.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.