Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2019
Effect of postdilatation following balloon expandable transcatheter aortic valve implantation.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kawaguchi Tomohiro, Yamaji Kyohei, Ishizu Kenichi, Morinaga Takashi, Hayashi Masaomi, Isotani Akihiro, Kakumoto Shinichi, Arai Yoshio, Sakaguchi Genichi, Shirai Shinichi, Ando Kenji
Аннотация
BACKGROUND: Postdilatation after transcatheter heart valve (THV) implantation was associated with larger aortic valve areas in large-scale registries; however, the specific effects of postdilatation are poorly understood.
METHODS AND RESULTS: Among a total of 224 consecutive patients who underwent transcatheter aortic valve replacement using SAPIEN 3, 121 patients (54.0%) underwent postdilatation (same contrast volume: N = 101, +1 ml: N = 17, +2 ml: N = 3). THV diameter was assessed (a) during, (b) after implantation, (c) during postdilatation, and (d) after postdilatation by quantitative fluoroscopy. In the overall patients (N = 224), acute recoil was observed from during implantation (23.0 ± 2.0 mm) to after implantation (22.5 ± 2.0 mm, p < .001) with an absolute recoil of 0.52 ± 0.25 mm. After postdilatation (N = 121), THV diameter significantly increased from 22.5 ± 2.0 mm to 22.9 ± 2.1 mm (p < .001), with smaller absolute recoil (0.39 ± 0.21 mm, p < .001). Compared with those who did not undergo postdilatation, patients who underwent postdilatation had larger postprocedural THV area assessed by multi-slice computed tomography (471.4 ± 78.1 mm2 vs. 447.5 ± 76.3 mm2 , p = .02) and larger effective orifice area (EOA) assessed by echocardiography throughout 1 year (at 30 day, 1.66 ± 0.33 cm2 vs. 1.45 ± 0.27 cm2 , p < .001; at 6 month, 1.66 ± 0.33 cm2 vs. 1.44 ± 0.29 cm2 , p < .001; at 1 year, 1.69 ± 0.38 cm2 vs. 1.47 ± 0.30 cm2 , p < .001).
CONCLUSIONS: Postdilatation after implantation of the SAPIEN 3 valve produced a larger THV diameter with less acute recoil, followed by larger EOA throughout 1 year. Further studies are needed to evaluate the impact of postdilatation on long-term clinical outcomes.
METHODS AND RESULTS: Among a total of 224 consecutive patients who underwent transcatheter aortic valve replacement using SAPIEN 3, 121 patients (54.0%) underwent postdilatation (same contrast volume: N = 101, +1 ml: N = 17, +2 ml: N = 3). THV diameter was assessed (a) during, (b) after implantation, (c) during postdilatation, and (d) after postdilatation by quantitative fluoroscopy. In the overall patients (N = 224), acute recoil was observed from during implantation (23.0 ± 2.0 mm) to after implantation (22.5 ± 2.0 mm, p < .001) with an absolute recoil of 0.52 ± 0.25 mm. After postdilatation (N = 121), THV diameter significantly increased from 22.5 ± 2.0 mm to 22.9 ± 2.1 mm (p < .001), with smaller absolute recoil (0.39 ± 0.21 mm, p < .001). Compared with those who did not undergo postdilatation, patients who underwent postdilatation had larger postprocedural THV area assessed by multi-slice computed tomography (471.4 ± 78.1 mm2 vs. 447.5 ± 76.3 mm2 , p = .02) and larger effective orifice area (EOA) assessed by echocardiography throughout 1 year (at 30 day, 1.66 ± 0.33 cm2 vs. 1.45 ± 0.27 cm2 , p < .001; at 6 month, 1.66 ± 0.33 cm2 vs. 1.44 ± 0.29 cm2 , p < .001; at 1 year, 1.69 ± 0.38 cm2 vs. 1.47 ± 0.30 cm2 , p < .001).
CONCLUSIONS: Postdilatation after implantation of the SAPIEN 3 valve produced a larger THV diameter with less acute recoil, followed by larger EOA throughout 1 year. Further studies are needed to evaluate the impact of postdilatation on long-term clinical outcomes.