DOI 10.1002/ccd.28512

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2019

Initial experience of a self-expanding transcatheter aortic valve with an outer pericardial wrap: The United Kingdom and Ireland Implanters' registry.

Dowling Cameron, Firoozi Sami, Panoulas Vasileios, Dalby Miles, Kashyap Mavin N, Kabir Tito, Kalogeras Konstantinos, Buch Mamta H, Levy Richard, Chowdhary Saqib, Saraf Smriti, Roberts David, More Ranjit, Wiper Andrew, Abdelaziz Hesham K, Neylon Antoinette, Mylotte Darren, Pisaniello Anthony D, Fraser Douglas G W, Anderson Richard, Cunnington Michael S, Malkin Christopher J, Blackman Daniel J, Brennan Paul F, Owens Colum G, Manoharan Ganesh, Spence Mark S, Brecker Stephen J

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

The United Kingdom and Ireland Implanters' registry is a multicenter registry which reports on real-world experience with new transcatheter heart valves.

BACKGROUND

The Evolut PRO (Medtronic, Minneapolis, MN) transcatheter aortic valve is a self-expanding transcatheter aortic valve with an outer pericardial wrap, designed to minimize paravalvular regurgitation.

METHODS

Between July 2017 and December 2018, clinical, procedural, and 30-day outcome data were prospectively collected from all patients receiving the Evolut PRO valve across nine participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2 (VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days.

RESULTS

A total of 317 patients underwent implantation. Mean age was 81.8 ± 6.4 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.5 ± 1.8%. Iliofemoral access was used in 99.1% of patients. Device success was 91.2%. Mean gradient was 7.6 ± 4.7 mmHg and effective orifice area 1.9 ± 0.7 cm2 . The incidence of moderate paravalvular regurgitation was 1.7% and there was no severe paravalvular regurgitation. A new permanent pacemaker was implanted in 17.8% of patients without a pacemaker at baseline. Early safety was demonstrated in 92.7%. At 30 days, all-cause mortality was 0.6%, stroke 3.8%, and major vascular complication 2.8%.

CONCLUSIONS

Real-world experience of the Evolut PRO transcatheter aortic valve demonstrated favorable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.

Для цитирования: Dowling Cameron, Firoozi Sami, Panoulas Vasileios, Dalby Miles, Kashyap Mavin N, Kabir Tito, Kalogeras Konstantinos, Buch Mamta H, Levy Richard, Chowdhary Saqib, Saraf Smriti, Roberts David, More Ranjit, Wiper Andrew, Abdelaziz Hesham K, Neylon Antoinette, Mylotte Darren, Pisaniello Anthony D, Fraser Douglas G W, Anderson Richard, Cunnington Michael S, Malkin Christopher J, Blackman Daniel J, Brennan Paul F, Owens Colum G, Manoharan Ganesh, Spence Mark S, Brecker Stephen J. Initial experience of a self-expanding transcatheter aortic valve with an outer pericardial wrap: The United Kingdom and Ireland Implanters' registry.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2019. DOI: 10.1002/ccd.28512.