Luraghi Giulia, Migliavacca Francesco, García-González Alberto, Chiastra Claudio, Rossi Alexia, Cao Davide, Stefanini Giulio, Rodriguez Matas Jose Felix
Аннотация
PURPOSE: Transcatheter aortic valve replacement (TAVR) is a minimally invasive treatment for high-risk patients with aortic diseases. Despite its increasing use, many influential factors are still to be understood and require continuous investigation. The best numerical approach capable of reproducing both the valves mechanics and the hemodynamics is the fluid-structure interaction (FSI) modeling. The aim of this work is the development of a patient-specific FSI methodology able to model the implantation phase as well as the valve working conditions during cardiac cycles.
METHODS: The patient-specific domain, which included the aortic root, native valve and calcifications, was reconstructed from CT images, while the CAD model of the device, metallic frame and pericardium, was drawn from literature data. Ventricular and aortic pressure waveforms, derived from the patient's data, were used as boundary conditions. The proposed method was applied to two real clinical cases, which presented different outcomes in terms of paravalvular leakage (PVL), the main complication after TAVR.
RESULTS: The results confirmed the clinical prognosis of mild and moderate PVL with coherent values of regurgitant volume and effective regurgitant orifice area. Moreover, the final release configuration of the device and the velocity field were compared with postoperative CT scans and Doppler traces showing a good qualitative and quantitative matching.
CONCLUSION: In conclusion, the development of realistic and accurate FSI patient-specific models can be used as a support for clinical decisions before the implantation.
METHODS: The patient-specific domain, which included the aortic root, native valve and calcifications, was reconstructed from CT images, while the CAD model of the device, metallic frame and pericardium, was drawn from literature data. Ventricular and aortic pressure waveforms, derived from the patient's data, were used as boundary conditions. The proposed method was applied to two real clinical cases, which presented different outcomes in terms of paravalvular leakage (PVL), the main complication after TAVR.
RESULTS: The results confirmed the clinical prognosis of mild and moderate PVL with coherent values of regurgitant volume and effective regurgitant orifice area. Moreover, the final release configuration of the device and the velocity field were compared with postoperative CT scans and Doppler traces showing a good qualitative and quantitative matching.
CONCLUSION: In conclusion, the development of realistic and accurate FSI patient-specific models can be used as a support for clinical decisions before the implantation.
Предметные рубрики MeSH
Aortic ValveAortic Valve InsufficiencyAortic Valve StenosisClinical Decision-MakingFinite Element AnalysisHeart Valve ProsthesisHemodynamicsHumansModels, CardiovascularNumerical Analysis, Computer-AssistedPatient SelectionPatient-Specific ModelingProsthesis DesignRetrospective StudiesSeverity of Illness IndexTomography, X-Ray ComputedTranscatheter Aortic Valve ReplacementTreatment OutcomeUltrasonography, Doppler