Acta cardiologica · 2019
Clinical outcomes of self-expandable vs. balloon-expandable TAVI for severe aortic stenosis.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Tham Jodie Li Mei, Adams Heath, Paleri Sarang, Wright Christine, Dimitriou Jim, Newcomb Andrew, MacIsaac Andrew I, Whitbourn Robert J, Palmer Sonny C
Аннотация
Background: Transcatheter aortic valve implantation (TAVI) is an established therapy for patients with severe aortic stenosis (AS). There is limited data exploring differences in outcomes post-TAVI SEV vs. BEV. This study compared procedural success and 30-d clinical outcomes self-expandable valves (SEV), vs. balloon-expandable valves (BEV) for patients with severe AS.Methods: Retrospective analysis was undertaken of patients receiving TAVI at St Vincent's Hospital, Melbourne between August 2009 and May 2018. The primary endpoints included procedural success, clinical outcomes and complication rates at 30-d.Results: Out of 151 patients undergoing TAVI, 70 received (46.3%) SEV (Medtronic CoreValve & Evolut-R) and 81 (53.6%) BEV (Edwards SAPIEN-XT & S3). The mean Society of Thoracic Surgery (STS) risk score did not differ between the groups, SEV (83.6 ± 4.9 years, STS 4.4 ± 3.8) compared to BEV (82.3 ± 5.8 years, STS 4.9 ± 4.9). Procedural success was similar SEV 67 (95.7%) vs. BEV 78 (96.3%). Rates of ≥ moderate paravalvular aortic regurgitation (PAR) at 30-d were significantly higher in SEV compared to BEV (6.7 vs. 0.0%; p = .02). SEV patients had higher rates of pacemaker insertion (36.4 vs. 9.5%; p = .001) and stroke rates (12.4 vs. 1.4%; p = .04) compared to BEV patients. The difference in 30-d mortality between the two groups was similar (SEV 4.6% vs. BEV 1.3%; p = .23).Conclusions: This real-world retrospective analysis demonstrates higher rates of ≥ moderate PAR, stroke and pacemaker insertion with SEV compared to BEV at 30 d post-TAVI for severe symptomatic AS.
Предметные рубрики MeSH
Aged, 80 and overAortic ValveAortic Valve InsufficiencyAortic Valve StenosisAustraliaFemaleHeart Valve ProsthesisHumansMaleOutcome and Process Assessment, Health CarePacemaker, ArtificialPostoperative ComplicationsProsthesis DesignRetrospective StudiesSeverity of Illness IndexStrokeTranscatheter Aortic Valve Replacement