Cardiovascular revascularization medicine : including molecular interventions · 2019
Outcomes of Direct Transcatheter Aortic Valve Replacement Without Balloon Aortic Valvuloplasty Using a New Generation Valve.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Aalaei-Andabili Seyed Hossein, Beaver Thomas M, Bavry Anthony A, Petersen John W, Karimi Ashkan, Wayangankar Siddharth, Arnaoutakis George, Anderson R David
Аннотация
PURPOSE: We investigated the outcomes of patients who underwent Transcatheter Aortic Valve Replacement (TAVR) with and without Balloon Aortic Valvuloplasty (BAV) using the SAPIEN 3 (S3) valve.
METHODS: All patients who underwent TAVR using S3 valve were included. The primary outcomes were the incidence of stroke and significant paravalvular leak (PVL). Secondary outcomes were the incidence of mortality, balloon post dilation, and need for permanent pacemaker.
RESULTS: From July-2014 to April-2018, 34 (9%) patients underwent BAV prior to TAVR and 344 (91%) patients underwent direct TAVR without BAV using the S3 valve. The Society of Thoracic Surgeons (STS) risk score was similar between two groups; 5.8 ± 3.5 in no BAV group and 5.4 ± 3.3 in BAV group, p = 0.53. After TAVR, 6 (1.7%) patients in no BAV group but no patient in BAV group developed stroke (p = 1.0). No patient had severe PVL and only 5 patients (1.3%) had moderate PVL at 30-day; 4 (1.2%) in no BAV group and 1 (2.9%) in BAV group (p = 0.38). Forty-six patients (13.4%) in the no BAV group and 4 (11.8%) patients in the BAV group needed balloon post dilation (p = 1.0). Six (1.6%) patients died during hospitalization, all in the no BAV group (p = 1.0). Forty-five (11.9%) patients needed new pacemaker implantation; 44 (12.8%) patients in no BAV group and 1 (2.9%) patient in BAV group (p = 0.1). Two-year survival rate was 85% in no BAV group and 84% in BAV group (p = 0.46).
CONCLUSIONS: TAVR using S3 valves is associated with very low rates of post-TAVR stroke and significant PVL. Outcomes of direct TAVR are similar to the outcomes of TAVR with BAV, without an increased rate of stroke, significant PVL, or balloon post dilation.
METHODS: All patients who underwent TAVR using S3 valve were included. The primary outcomes were the incidence of stroke and significant paravalvular leak (PVL). Secondary outcomes were the incidence of mortality, balloon post dilation, and need for permanent pacemaker.
RESULTS: From July-2014 to April-2018, 34 (9%) patients underwent BAV prior to TAVR and 344 (91%) patients underwent direct TAVR without BAV using the S3 valve. The Society of Thoracic Surgeons (STS) risk score was similar between two groups; 5.8 ± 3.5 in no BAV group and 5.4 ± 3.3 in BAV group, p = 0.53. After TAVR, 6 (1.7%) patients in no BAV group but no patient in BAV group developed stroke (p = 1.0). No patient had severe PVL and only 5 patients (1.3%) had moderate PVL at 30-day; 4 (1.2%) in no BAV group and 1 (2.9%) in BAV group (p = 0.38). Forty-six patients (13.4%) in the no BAV group and 4 (11.8%) patients in the BAV group needed balloon post dilation (p = 1.0). Six (1.6%) patients died during hospitalization, all in the no BAV group (p = 1.0). Forty-five (11.9%) patients needed new pacemaker implantation; 44 (12.8%) patients in no BAV group and 1 (2.9%) patient in BAV group (p = 0.1). Two-year survival rate was 85% in no BAV group and 84% in BAV group (p = 0.46).
CONCLUSIONS: TAVR using S3 valves is associated with very low rates of post-TAVR stroke and significant PVL. Outcomes of direct TAVR are similar to the outcomes of TAVR with BAV, without an increased rate of stroke, significant PVL, or balloon post dilation.
Предметные рубрики MeSH
AgedAged, 80 and overAortic ValveAortic Valve InsufficiencyAortic Valve StenosisArrhythmias, CardiacBalloon ValvuloplastyCardiac Pacing, ArtificialFemaleHeart Valve ProsthesisHemodynamicsHospital MortalityHumansMaleProsthesis DesignRetrospective StudiesRisk FactorsStrokeTime FactorsTranscatheter Aortic Valve ReplacementTreatment Outcome