Blackman Daniel J, Saraf Smriti, MacCarthy Philip A, Myat Aung, Anderson Simon G, Malkin Christopher J, Cunnington Michael S, Somers Kathryn, Brennan Paul, Manoharan Ganesh, Parker Jessica, Aldalati Omar, Brecker Stephen J, Dowling Cameron, Hoole Stephen P, Dorman Stephen, Mullen Michael, Kennon Simon, Jerrum Melanie, Chandrala Pavan, Roberts David H, Tay Justin, Doshi Sagar N, Ludman Peter F, Fairbairn Timothy A, Crowe Joanne, Levy Richard D, Banning Adrian P, Ruparelia Neil, Spence Mark S, Hildick-Smith David

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Very little is known about long-term valve durability after transcatheter aortic valve replacement (TAVR).

OBJECTIVES

This study sought to evaluate the incidence of structural valve degeneration (SVD) 5 to 10 years post-procedure.

METHODS

Demographic, procedural, and in-hospital outcome data on patients who underwent TAVR from 2007 to 2011 were obtained from the U.K. TAVI (United Kingdom Transcatheter Aortic Valve Implantation) registry. Patients in whom echocardiographic data were available both at baseline and ≥5 years post-TAVR were included. Hemodynamic SVD was determined according to European task force committee guidelines.

RESULTS

A total of 241 patients (79.3 ± 7.5 years of age; 46% female) with paired post-procedure and late echocardiographic follow-up (median 5.8 years, range 5 to 10 years) were included. A total of 149 patients (64%) were treated with a self-expandable valve and 80 (34.7%) with a balloon-expandable valve. Peak aortic valve gradient at follow-up was lower than post-procedure (17.1 vs. 19.1 mm Hg; p = 0.002). More patients had none/trivial aortic regurgitation (AR) (47.5% vs. 33%), and fewer had mild AR (42.5% vs. 57%) at follow-up (p = 0.02). There was 1 case (0.4%) of severe SVD 5.3 years after implantation (new severe AR). There were 21 cases (8.7%) of moderate SVD (mean 6.1 years post-implantation; range 4.9 to 8.6 years). Twelve of these (57%) were due to new AR and 9 (43%) to restenosis.

CONCLUSIONS

Long-term transcatheter aortic valve function is excellent. In the authors' study, 91% of patients remained free of SVD between 5 and 10 years post-implantation. The incidence of severe SVD was <1%. Moderate SVD occurred in 1 in 12 patients.

Для цитирования: Blackman Daniel J, Saraf Smriti, MacCarthy Philip A, Myat Aung, Anderson Simon G, Malkin Christopher J, Cunnington Michael S, Somers Kathryn, Brennan Paul, Manoharan Ganesh, Parker Jessica, Aldalati Omar, Brecker Stephen J, Dowling Cameron, Hoole Stephen P, Dorman Stephen, Mullen Michael, Kennon Simon, Jerrum Melanie, Chandrala Pavan, Roberts David H, Tay Justin, Doshi Sagar N, Ludman Peter F, Fairbairn Timothy A, Crowe Joanne, Levy Richard D, Banning Adrian P, Ruparelia Neil, Spence Mark S, Hildick-Smith David. Long-Term Durability of Transcatheter Aortic Valve Prostheses.. Journal of the American College of Cardiology. 2019. DOI: 10.1016/j.jacc.2018.10.078.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.