[Refraction changes after cataract extraction with IOL implantation in the eyes with previous performed vitrectomy].

Bilińska Ewa, Nawrocki Jerzy, Suprunowicz Irena, Omulecki Wojciech

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine differences between the predicted and postoperative refraction after cataract extraction with intraocular lens implantation in the eyes, which previous underwent vitrectomy.

MATERIAL AND

METHODS

Fifty three eyes of 52 patients underwent the analysis: twenty five in group I, nineteen in group II and nine eyes with previous scleral buckling in group III. All the eyes had ECCE and IOL with PMMA implantation after vitrectomy. In groups II and. III silicone oil tamponade was used and removed before cataract extraction. Thirty eyes of the control group K underwent cataract surgery and IOL implantation alone. The IOL power calculation was performed with SRK II formula. The predicted and postoperative refractions were compared. The follow-up was minimum 4 months (on average 15 +/- 12.71 months).

RESULTS

The postoperative refractions were significantly shifted toward myopia than it was predicted--1.41 +/- 1.21 D in group I, -0.81 +/- 2.11 D in group II and -3.03 +/- 1.49 D in group III. In the control group K the difference was--0.07 +/- 0.91.

CONCLUSIONS

Myopic shift of postoperative refraction after cataract surgery should be considered, when calculating the IOL power in the eye after vitreoretinal procedures.

Для цитирования: Bilińska Ewa, Nawrocki Jerzy, Suprunowicz Irena, Omulecki Wojciech. [Refraction changes after cataract extraction with IOL implantation in the eyes with previous performed vitrectomy].. Klinika oczna. 2002.