Comparison of 4 methods for quantifying posterior capsule opacification.

Findl Oliver, Buehl Wolf, Menapace Rupert, Georgopoulos Michael, Rainer Georg, Siegl Hannes, Kaider Alexandra, Pinz Axel

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare the results of posterior capsule opacification (PCO) quantification and the repeatability of a fully automated analysis system (Automated Quantification of After-Cataract [AQUA]) with that of 2 other quantification methods and subjective grading of PCO. A test set of digital retroillumination images of 100 eyes with PCO of varying degrees was used.

SETTING

Department of Ophthalmology, University of Vienna, Vienna, Austria.

METHODS

One hundred digital retroillumination images of eyes (100 patients) with PCO were selected to attain an even distribution from mild to severe cases. The images were evaluated by 4 methods: subjective grading by 4 experienced and 4 inexperienced examiners, the subjective Evaluation of Posterior Capsular Opacification (EPCO) system, posterior capsule opacification (POCO) software, and the AQUA system. Ten images were presented twice to assess the reproducibility of the analysis systems.

RESULTS

Subjective grading correlated best with the subjective EPCO system and the objective AQUA system (r = 0.94 and r = 0.93, respectively). The POCO system showed very early saturation and therefore a much weaker correlation (r = 0.73). The POCO scores reached the maximum of 100% in several minimal to mild PCO cases. The reproducibility of the AQUA software was perfect and that of the other analysis systems, comparably satisfactory.

CONCLUSION

The objective AQUA score correlated well with subjective methods including the EPCO system. The POCO system, which assesses PCO area, did not adequately describe PCO intensity and includes a subjective step in the analysis process. The AQUA system could become an important tool for randomized masked trials of PCO inhibition.

Для цитирования: Findl Oliver, Buehl Wolf, Menapace Rupert, Georgopoulos Michael, Rainer Georg, Siegl Hannes, Kaider Alexandra, Pinz Axel. Comparison of 4 methods for quantifying posterior capsule opacification.. Journal of cataract and refractive surgery. 2003. DOI: 10.1016/s0886-3350(02)01509-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.