MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/bmc.1496

Медицинская библиотека · Biomedical chromatography : BMC · 2010

Simultaneous quantification of total eicosapentaenoic acid, docosahexaenoic acid and arachidonic acid in plasma by high-performance liquid chromatography-tandem mass spectrometry.

Salm Paul, Taylor Paul J, Kostner Karam

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

A method for the simultaneous quantification of eicosapentaenoic acid (EPA), docosahexaenoic acid (DHA) and arachidonic acid (AA) in human plasma by HPLC-tandem mass spectrometry (HPLC-MS/MS) was developed and validated. Free and esterified forms of fatty acids were hydrolysed from plasma samples in the presence of an internal standard and subjected to liquid-liquid extraction. The chromatographic run time was 3.5 min per sample. The assay was linear from 0.5 to 300 mg/L (r(2) > 0.997, n = 18). Based on matrix addition, accuracy deviation was <15%, except for AA at 10 mg/L (30-90%), whereas precision was <8% for all fatty acids studied. The method was applied to the measurement of these omega-3 fatty acids in a fish oil supplement study with healthy volunteers. Healthy males (n = 4) were administered a supplement containing 465 mg EPA and 375 mg DHA per capsule (Omacor®). A dose of two capsules was given daily over a 4 week period. Pre-treatment concentrations varied between subjects for EPA (17-68 mg/L), DHA (36-63 mg/L) and AA (121-248 mg/L). During the dosing period EPA increased 460-480% from the baseline concentration, while DHA increased 150-160%. The EPA-AA ratio increased from 0.07-0.56 to 0.3-3.1 after 4 weeks of dosing. In conclusion, the method described could be suitable for monitoring EPA, DHA and AA in clinical studies that may aid in achieving optimal concentrations of these fatty acids in patients who could be at risk of sudden cardiac death.

Для цитирования: Salm Paul, Taylor Paul J, Kostner Karam. Simultaneous quantification of total eicosapentaenoic acid, docosahexaenoic acid and arachidonic acid in plasma by high-performance liquid chromatography-tandem mass spectrometry.. Biomedical chromatography : BMC. 2010. DOI: 10.1002/bmc.1496.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.