Медицинская библиотека · Chang Gung medical journal · 2001

Endothelial cell loss induced by phacoemulsification occurs through apoptosis.

Lai L J, Chen Y F, Wu S, Tsao Y P, Tsai R J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Cornea endothelial cells are nondividing cells containing pumping function which is crucial for cornea clarity and integrity. Endothelial cell loss occurs after cataract surgical procedures such as phacoemulsification. The authors hypothesize that endothelium damage occurs through apoptosis.

METHODS

Ultrasound was achieved by placing a phacoemulsification probe in the anterior chamber and delivering 0% or 50% of maximum power for 2.5 min. The corneal tissue was harvested immediately, and at 1 and 7 days after the operation. Corneal tissue was stained by hemotoxylin and eosin (H&E) and evaluated by light microscopy. Endothelium apoptosis was monitored using the terminal deoxynucleotidyl transferase-mediated dUTP-digoxigenin nick-end labeling (TUNEL) assay to detect DNA fragmentation.

RESULTS

In corneas which underwent phacoemulsification with 0% energy, no cell loss or apoptosis was identified immediately, 1 or 7 days after the operation. Likewise, in corneas exposed to 50% energy, no cell loss or apoptosis was detected immediately after phacoemulsification. However, minimal amount of cell loss but prominent apoptosis was detected with the TUNEL assay 1 day after the operation, whereas significant cell loss but no apoptosis was detected 7 days after the operation by H&E stain.

CONCLUSIONS

These results demonstrate that corneal endothelial cell loss induced by ultrasound damage occurs through apoptosis.

Для цитирования: Lai L J, Chen Y F, Wu S, Tsao Y P, Tsai R J. Endothelial cell loss induced by phacoemulsification occurs through apoptosis.. Chang Gung medical journal. 2001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.