Journal of cataract and refractive surgery · 2001

Inflammation after phacoemulsification in diabetic retinopathy. Foldable acrylic versus heparin-surface-modified poly(methyl methacrylate) intraocular lenses.

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Krepler K, Ries E, Derbolav A, Nepp J, Wedrich A

Аннотация

PURPOSE: To evaluate inflammation after cataract surgery in patients with nonproliferative diabetic retinopathy (NPDR) and compare results with 2 intraocular lenses (IOLs): a foldable hydrophobic acrylic and a heparin-surface-modified (HSM) poly(methyl methacrylate) (PMMA).

SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria.

METHODS: Patients with NPDR were randomized for implantation of an HSM PMMA IOL (811C, Pharmacia) through a 6.0 mm sclerocorneal incision (30 patients) or a foldable hydrophobic acrylic IOL (AcrySof, Alcon) through a 4.0 mm sclerocorneal incision (32 patients). Both IOLs had 6.0 mm optics. All patients were treated according to a standardized protocol. The degree of flare in the anterior chamber was measured with the Kowa 1000 laser flare-cell meter 1 day preoperatively and 1 day, 1 week, and 1 and 3 months postoperatively.

RESULTS: In both IOL groups, flare was highest on the first postoperative day and decreased to preoperative levels by 3 months after surgery. There was no statistically significant difference in relative flare values between the 2 groups.

CONCLUSION: There was no difference in postoperative inflammation in eyes with a foldable hydrophobic acrylic IOL implanted through a small incision and those with a rigid HSM PMMA IOL. Postoperative inflammation results indicate that the lenses are equally suitable for the use in patients with diabetic retinopathy.