MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2017/9874068

Медицинская библиотека · Canadian respiratory journal · 2017

Is There a Correlation between New Scoring Systems and Systemic Inflammation in Stable Bronchiectasis?

Coban Hikmet, Gungen Adil Can

СтатьяПеревод пока не подготовлен

Аннотация

AIM: The present study aimed to investigate the relation between FACED and BSI scores, which were developed to measure the severity of bronchiectasis, and systemic inflammation in patients with stable bronchiectasis.

METHODS

FACED and BSI scores of 117 patients with stable bronchiectasis were calculated. The correlations between mean scores and CRP levels, leukocyte count, and neutrophil/lymphocyte ratio were investigated.

FINDINGS: Mean BSI and FACED scores were 7.2 ± 5.2 and 2.1 ± 1.8, respectively. The severity of bronchiectasis as determined based on BSI and FACED increased significantly with increasing levels of CRP in patients with stable bronchiectasis (p=0.001 and p=0.027, resp.). No significant changes were found in leukocyte count (p=0.72 and p=0.09, resp.) and N/L ratio (p=0.45 and p=0.71, resp.). BSI and FACED scores were significantly correlated with CRP but not with leukocyte count or N/L ratio.

CONCLUSION

In patients with stable bronchiectasis who are evaluated based on FACED and BSI scores, CRP can be a useful biomarker as a direct indicator of the severity of systemic inflammation.

Для цитирования: Coban Hikmet, Gungen Adil Can. Is There a Correlation between New Scoring Systems and Systemic Inflammation in Stable Bronchiectasis?. Canadian respiratory journal. 2017. DOI: 10.1155/2017/9874068.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.