MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circinterventions.123.013238

Медицинская библиотека · Circulation. Cardiovascular interventions · 2023

Feasibility of Coronary Access Following Redo-TAVR for Evolut Failure: A Computed Tomography Simulation Study.

Tang Gilbert H L, Spencer Julianne, Rogers Toby, Grubb Kendra J, Gleason Patrick, Gada Hemal, Mahoney Paul, Dauerman Harold L, Forrest John K, Reardon Michael J, Blanke Philipp, Leipsic Jonathon A, Abdel-Wahab Mohamed, Attizzani Guilherme F, Puri Rishi, Caskey Michael, Chung Christine J, Chen Ying-Hwa, Dudek Dariusz, Allen Keith B, Chhatriwalla Adnan K, Htun Wah Wah, Blackman Daniel J, Tarantini Giuseppe, Zhingre Sanchez Jorge, Schwartz Greta, Popma Jeffrey J, Sathananthan Janarthanan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Coronary accessibility following redo-transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging.

METHODS

A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5.

RESULTS

With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 (P<0.001). Coronary accessibility improved with a 5-mm Evolut implant depth: 97% at node 4 and 65% at node 5 (P<0.001). When comparing 3- to 5-mm Evolut implant depth, sinus sequestration was the lowest with Sapien-3 outflow at Evolut node 4 (13% versus 2%; P<0.001), and the highest at Evolut node 5 (61% versus 32%; P<0.001).

CONCLUSIONS

Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR.

REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02701283.

Для цитирования: Tang Gilbert H L, Spencer Julianne, Rogers Toby, Grubb Kendra J, Gleason Patrick, Gada Hemal, Mahoney Paul, Dauerman Harold L, Forrest John K, Reardon Michael J, Blanke Philipp, Leipsic Jonathon A, Abdel-Wahab Mohamed, Attizzani Guilherme F, Puri Rishi, Caskey Michael, Chung Christine J, Chen Ying-Hwa, Dudek Dariusz, Allen Keith B, Chhatriwalla Adnan K, Htun Wah Wah, Blackman Daniel J, Tarantini Giuseppe, Zhingre Sanchez Jorge, Schwartz Greta, Popma Jeffrey J, Sathananthan Janarthanan. Feasibility of Coronary Access Following Redo-TAVR for Evolut Failure: A Computed Tomography Simulation Study.. Circulation. Cardiovascular interventions. 2023. DOI: 10.1161/circinterventions.123.013238.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.