m+Medelevator.RU
← Поиск публикаций
The Thoracic and cardiovascular surgeon · 2023

A Controlled Trial Comparing One-Year Hemodynamics of Two Bovine Pericardial Valves.

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеEquivalence TrialНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sohn Suk Ho, Kang Yoonjin, Kim Ji Seong, Choi Jae Woong, Lee Jae Hang, Kim Jun Sung, Lim Cheong, Hwang Ho Young

Аннотация

BACKGROUND: This randomized controlled trial was designed to compare 1-year hemodynamic performances and clinical outcomes after aortic valve replacement (AVR) using a recently introduced (the AVALUS group) and worldwide used (the CEPME group) bovine pericardial bioprostheses.

METHODS: Patients were screened to enroll 70 patients in each group based on a noninferiority design. The primary endpoint of the trial was the mean pressure gradient across the aortic valve (AVMPG) at 1 year after surgery. One-year echocardiographic data were obtained from 92.1% (129 of 140 patients) of the study patients.

RESULTS: There were no differences in baseline characteristics, including sex and body surface area (1.64 ± 0.18 vs. 1.65 ± 0.15 m2) between the groups. The AVMPG on 1-year echocardiography was 14.0 ± 4.3 and 13.9 ± 5.1 mmHg in the AVALUS and CEPME groups, respectively (the p-value for noninferiority was 0.0004). In the subgroup analyses for the respective size of the prostheses, AVMPG of the 19-mm prostheses was significantly lower in the AVALUS group than in the CEPME group (14.0 ± 4.3 vs. 20.0 ± 4.7 mmHg, p = 0.012), whereas those of the other sizes were not significantly different between the two groups. There were no significant differences in the effective orifice area (1.49 ± 0.40 vs. 1.53 ± 0.38 cm2, p = 0.500) or effective orifice area index (0.91 ± 0.22 vs 0.93 ± 0.23 cm2/m2, p = 0.570) in all the patients, or in the subgroup analysis for the 19-mm prosthesis. There were no differences in the 1-year clinical outcomes between the two groups.

CONCLUSION: The 1-year hemodynamic and clinical outcomes of the AVALUS group were noninferior to those of the CEPME group (NCT03796442).

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты