Fractional Flow Reserve to Assess Coronary Artery Disease in Patients with Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation: Long-Term Outcomes.
Аннотация
BACKGROUND
The long-term outcomes of patients undergoing functional assessment of coronary lesions with fractional flow reserve (FFR) while awaiting transcatheter aortic valve implantation (TAVI) are unknown. Data on the safety of intracoronary adenosine use in this setting are scarce. The objectives of this study were to describe (1) the long-term outcomes based on the coronary artery disease (CAD) assessment strategy used and (2) the safety of intracoronary adenosine in patients with severe aortic stenosis (AS).
METHODS
1023 patients with severe AS awaiting TAVI were included. Patients were classified according to their CAD assessment strategy: angiography guided or FFR guided. Patients were further subdivided according to the decision to proceed with percutaneous coronary intervention (PCI): angiography-guided PCI (375/1023), angiography-guided no-PCI (549/1023), FFR-guided PCI (50/1023), and FFR-guided no-PCI (49/1023). Patients were followed up for the occurrence of major adverse cardiac and cerebrovascular events (MACCEs).
RESULTS
At a mean follow-up of 33.7 months, we observed no significant differences in terms of major adverse cardiovascular and cerebrovascular events (MACCE) in the angiography-guided group (42.4%) compared with the FFR-guided group (37.4%) (p = 0.333). When comparing outcomes of the FFR-guided no-PCI group (32.7%) with the angiography-guided PCI group (46.4%), no significant difference was noted (p = 0.999). Following intracoronary adenosine, a single adverse event occurred.
CONCLUSIONS
In this population, intracoronary adenosine is safe and well tolerated. We found no significant benefit to an FFR-guided strategy compared with an angiography-guided strategy with respect to MACCEs. Although clinically compelling, avoiding the procedural risks of PCI by deferring the intervention in functionally insignificant lesions failed to show a statistically significant benefit.