DOI 10.1007/s00595-023-02722-9
The comparison of the clinical outcomes and costs between surgical aortic valve replacement and transcatheter aortic valve implantation based on the Japanese Diagnosis Procedure Combination database.
Аннотация
PURPOSE: We evaluated the clinical outcomes and costs of surgical aortic valve replacement (SAVR) and transfemoral transcatheter aortic valve implantation (TAVI) for aortic stenosis using the Japanese Diagnosis Procedure Combination (DPC) database.
METHODS
Using our extraction protocol, we retrospectively analyzed summary tables in the DPC database from 2016 to 2019, which were provided by the Ministry of Health, Labor and Welfare. A total of 27,278 patients were available (SAVR, n = 12,534; TAVI, n = 14,744).
RESULTS
The TAVI group was older than the SAVR group (SAVR vs. TAVI: 74.6 vs. 84.5 years; P < 0.01), with a lower in-hospital mortality (1.0 vs. 0.6%; P < 0.01) and a shorter hospital stay (26.9 vs. 20.3 days; P < 0.01). TAVI conferred more total medical service reimbursement points than SAVR (493,944 vs. 605,241 points; P < 0.01), especially materials points (147,830 vs. 434,609 points; P < 0.01). Total insurance claims for TAVI were approximately 1 million yen higher than those for SAVR. Regarding the details of costs, only the operation cost was higher, while other costs were lower with TAVI than with SAVR.
CONCLUSION
Our analysis revealed that both SAVR and TAVI showed acceptable clinical outcomes. TAVI was associated with higher total insurance claims than SAVR. If the material cost of TAVI operations can be reduced, greater cost-effectiveness can be expected.