BACKGROUND

Calprotectin is a calcium-binding protein that can be measured in serum, plasma, and feces. Increased serum and plasma calprotectin concentrations have been found in chronic inflammatory rheumatic disorders. An analytical and clinical evaluation of the DiaSorin Liaison® fecal Calprotectin assay using LIAISON® XL was performed.

METHODS

The protocol included an analytical and clinical evaluation in which imprecision, the linearity of dilution, differences between serum and plasma samples and method comparison with CalproLab™ ELISA kit were assessed. Serum calprotectin concentrations in active (n = 26) and remission (n = 23) rheumatoid arthritis (RA) patients were compared.

RESULTS

The intra-day and inter-day analytical imprecision CVs ranged from 2.9% to 4.0% and 2.7% to 10.4%, respectively. Correlation between measured and expected values was high (R > 0.99), indicating good linearity. The Wilcoxon signed-rank test showed that serum and plasma matched samples presented statistically significant differences (p < 0.001) being the highest concentrations of calprotectin observed in serum samples. Deming regression equation was as follows: Diasorin calprotectin (μg/ml) = -0.32 (95% CI: -0.65 - -0.05) +1.58 (95% CI: 1.42-1.79).* Calprolab calprotectin (μg/ml). Significantly higher serum calprotectin levels were found in RA patients with active disease when compared to patients with low disease activity or in clinical remission (mean ± SD) [(3.35 μg/ml ± 1.55) vs. (1.63 μg/ml ± 0.52), p < 0.001] and these levels correlated well with all disease activity indices.

CONCLUSIONS

The DiaSorin Liaison® fecal Calprotectin assay adapted for serum samples showed adequate technical performances and the clinical performances were similar to other assays.

Для цитирования: Macias-Muñoz Laura, Frade-Sosa Beatriz, Iniciarte-Mundo Jose, Hidalgo Susana, Morla Rosa Maria, Gallegos Yadira, Sanmarti Raimon, Auge Josep Maria. Analytical and clinical evaluation of DiaSorin Liaison® Calprotectin fecal assay adapted for serum samples.. Journal of clinical laboratory analysis. 2022. DOI: 10.1002/jcla.24258.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.