DOI 10.1161/01.str.0000242481.38262.7b

Медицинская библиотека · Stroke · 2006

Safety, feasibility, and short-term follow-up of drug-eluting stent placement in the intracranial and extracranial circulation.

Gupta Rishi, Al-Ali Firas, Thomas Ajith J, Horowitz Michael B, Barrow Thomas, Vora Nirav A, Uchino Ken, Hammer Maxim D, Wechsler Lawerence R, Jovin Tudor G

Сравнительное исследованиеОценочное исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: The use of bare metal stents to treat symptomatic intracranial stenosis may be associated with significant restenosis rates. The advent of drug-eluting stents (DESs) in the coronary circulation has resulted in a reduction of restenosis rates. We report our technical success rate and short-term restenosis rates after stenting with DESs in the intracranial and extracranial circulation.

METHODS

This study was a retrospective review of the period between April 1, 2004, and April 15, 2006, of 59 patients with 62 symptomatic intracranial or extracranial atherosclerotic lesions at 2 medical centers (University of Pittsburgh and Borgess Medical Center).

RESULTS

The mean age of our cohort was 61+/-12 years. The location of the 62 lesions was as follows: extracranial vertebral artery 31 (50%), intracranial vertebral artery or basilar artery 18 (29%), extracranial internal carotid artery (ICA) near the petrous bone 5 (8%), and intracranial ICA 8 (13%). There were 2 (3%) periprocedural complications: 1 non-flow-limiting dissection and 1 disabling stroke. Fifty vessels were available for follow-up angiography or computed tomography angiography at a median time of 4.0+/-2 months. A total of 2 of 36 extracranial stents (7%) and 1 of 26 intracranial stents (5%) were found to have restenosis > or = 50% at follow-up.

CONCLUSIONS

This report demonstrates that DES delivery in the intracranial and extracranial circulation is technically feasible. A small percentage of patients developed short-term in-stent restenosis. Longer-term follow-up is required in the setting of a prospective study to determine the late restenosis rates for DESs in comparison with bare metal stents.

Для цитирования: Gupta Rishi, Al-Ali Firas, Thomas Ajith J, Horowitz Michael B, Barrow Thomas, Vora Nirav A, Uchino Ken, Hammer Maxim D, Wechsler Lawerence R, Jovin Tudor G. Safety, feasibility, and short-term follow-up of drug-eluting stent placement in the intracranial and extracranial circulation.. Stroke. 2006. DOI: 10.1161/01.str.0000242481.38262.7b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.