MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.heliyon.2024.e41542

Медицинская библиотека · Heliyon · 2024

Investigation of 3D iris morphology early alteration after implantable collamer lens implantation by using SS-OCT.

Zhang Zhengwei, Chang Shuimiao, Li Kaiwen, Yao Jinhan, Wang Zhao, Liu Jiewei, Jiang Lin, Chai Feiyan, Wang Xiaogang

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Using a fully automated multitask deep learning method, which enabled simultaneous segmentation and quantification of all major anterior segment structures with swept-source optical coherence tomography (SS-OCT), we aimed to investigate the three-dimensional (3D) alterations in iris morphology before and after implantable collamer lens (ICL) surgery.

METHODS

All enrolled patients underwent anterior segment SS-OCT (ANTERION) within one week before and after ICL surgery. A multitask network automatically performed iris SS-OCT image segmentation and quantitative measurements of 3D iris morphology (iris thickness and volume of the inner 1-mm annular area and the outer 1-2-mm annular area, iris curvature [I-Curve], and iris smooth index [SI]).

RESULTS

Forty-six eyes of 27 patients (average age, 26.0 ± 5.3 years) were included in the final data analysis. The spherical equivalent ranged from -15.75 to -4.00 diopters (D). The mean ICL vault values were 537.92 ± 161.69 μm, which positively and significantly correlated with the pre- (r = 0.333, P = 0.024) and postoperative (r = 0.351, P = 0.017) anterior chamber depth (ACD). The mean pupil diameter significantly decreased, whereas both ACD and lens thickness significantly increased postoperatively. The iris thickness, iris volume of the inner 1-mm annular area and the outer 1-2-mm annular area, and SI decreased significantly within one week after ICL implantation. All mean values of the I-Curve increased dramatically postoperatively.

CONCLUSION

Iris morphology, ACD, and lens thickness were significantly altered after ICL implantation.

Для цитирования: Zhang Zhengwei, Chang Shuimiao, Li Kaiwen, Yao Jinhan, Wang Zhao, Liu Jiewei, Jiang Lin, Chai Feiyan, Wang Xiaogang. Investigation of 3D iris morphology early alteration after implantable collamer lens implantation by using SS-OCT.. Heliyon. 2024. DOI: 10.1016/j.heliyon.2024.e41542.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.