DOI 10.3390/bioengineering11121195

Медицинская библиотека · Bioengineering (Basel, Switzerland) · 2024

Comparison of Phacoemulsification and Aspiration Parameters in Cataract Surgery: Metal Tip vs. Hybrid Tip.

Ichikawa Kazuo, Ichikawa Kei, Tokiwa Seiji, Sato Yuki, Miyazaki Tomoyuki, Tanaka Yoshiki, Yamamoto Naoki

СтатьяПеревод пока не подготовлен

Аннотация

Various tips are available for phacoemulsification in cataract surgery. Evidence-based data can inform ophthalmologists, especially inexperienced ones, on tip selection. We retrospectively evaluated the energy efficiency and other parameters of two ultrasonic phacoemulsification and aspiration tips across different nuclear hardness grades in 342 cataract patients (342 eyes) with nuclear hardness grades II to IV. Surgical procedures, ultrasound settings, and instrumentation were standardized. All surgeries were performed by one experienced doctor. We compared the metal INTREPID® Balanced Tip (M-tip) with the INTREPID® Hybrid Tip (P-tip), which has a polymer coating. The M-tip required significantly less total ultrasound time and cumulative dissipated energy (CDE) than the P-tip for grades III and IV, while the P-tip had a shorter aspiration time and less estimated fluid aspirated for grade II. No differences in corneal endothelial cell loss were observed. Lens rupture rates were low: 0.47% for the M-tip and 0.78% for the P-tip. Multiple regression analysis showed that CDE increased with nuclear hardness. These findings suggest that the M-tip is efficient for harder lenses, while the P-tip may be advantageous for softer lenses, informing optimal tip selection in cataract surgery. Further research is suggested to elucidate their clinical significance.

Для цитирования: Ichikawa Kazuo, Ichikawa Kei, Tokiwa Seiji, Sato Yuki, Miyazaki Tomoyuki, Tanaka Yoshiki, Yamamoto Naoki. Comparison of Phacoemulsification and Aspiration Parameters in Cataract Surgery: Metal Tip vs. Hybrid Tip.. Bioengineering (Basel, Switzerland). 2024. DOI: 10.3390/bioengineering11121195.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.