MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fopht.2026.1763171

Медицинская библиотека · Frontiers in ophthalmology · 2026

Laser doppler holography for choroidal blood flow assessment: a systematic review of technical capabilities, validation studies, and clinical applications.

Marco Giammanco Manfredi, Russo Ginevra Genziana Bazan, Giammanco Marco

СтатьяСистематический обзорПеревод пока не подготовлен

Аннотация

INTRODUCTION

Quantitative choroidal blood flow assessment is important for understanding chorioretinal diseases. Laser Doppler Holography (LDH) is a new non-invasive imaging technique that provides full-field, high-temporal-resolution assessments of ocular hemodynamics. This systematic review synthesizes evidence on LDH's technical capabilities, clinical applications, and provides normative reference values for choroidal vascular anatomy.

METHODS

A systematic search of the literature was undertaken in accordance with PRISMA guidelines. Studies that evaluated choroidal blood flow in humans using LDH were identified. Data on technical specifications, hemodynamic parameters, and vascular anatomy were extracted for narrative synthesis.

RESULTS

The comprehensive literature search resulted in 347 records, with 8 studies that met the inclusion criteria for qualitative synthesis, as well as 2 studies that could be included in the meta-analysis. The pooled mean diameter of the choroidal arteries was derived to be 134.2 μm (95% CI: 128.3 to 140.1 μm) based on the meta-analysis and demonstrated low levels of heterogeneity (I2 = 0).

DISCUSSION: The narrative synthesis found that LDH could assess choroidal vasculature, differentiate arteries from veins using both flow waveforms and spectral data, deliver quantitative data for hemodynamic parameters, and assess blood flow directionality. LDH is a promising and versatile technique to study choroidal blood flow quickly and non-invasively.

Для цитирования: Marco Giammanco Manfredi, Russo Ginevra Genziana Bazan, Giammanco Marco. Laser doppler holography for choroidal blood flow assessment: a systematic review of technical capabilities, validation studies, and clinical applications.. Frontiers in ophthalmology. 2026. DOI: 10.3389/fopht.2026.1763171.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.