MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/1081597x-20260218-01

Медицинская библиотека · Journal of refractive surgery (Thorofare, N.J. : 1995) · 2026

Sutureless Scleral Fixation of the Carlevale IOL: A 5-Year Retrospective Study.

Vaiano Agostino S, Greco Antonio, Marenco Maria, Garavelli Fabio, De Filippis Alessandro, Deplano Gerardo, Campa Claudio, Parisi Gugliemo, Giannaccare Giuseppe, Reibaldi Michele

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To report the surgical and refractive outcomes over a 5-year follow-up period in patients who underwent sutureless scleral fixation of a one-piece intraocular lens (IOL).

METHODS

A retrospective study was conducted at one single center involving consecutive patients undergoing sutureless scleral fixation of one-piece IOL implantation, between September 2016 and May 2020. Visual acuity, refractive outcomes, and complications were assessed over a minimum 60-month follow-up period.

RESULTS

The study included 28 eyes of 28 patients (7 women and 21 men; mean age 61.0 ± 19.4 years [95% CI: 53.4 to 68.5]). Five years after surgery, mean corrected distance visual acuity significantly improved from 1.1 ± 0.6 logarithm of the minimum angle of resolution (95% CI: 0.9 to 1.3) to 0.5 ± 0.6 (95% CI: 0.3 to 0.8 logarithm of the minimum angle of resolution) (P < .001) with a mean refractive prediction error of -0.04 ± 1.30 diopters (95% CI: -0.53 to +0.45 diopters). After surgery mean endothelial cell count significantly decreased from 2,037 ± 455 cells/mm2 (95% CI: 1,861 to 2,213 cells/mm2) to 1,704 ± 483 cells/mm2 (95% CI: 1,517 to 1,891 cells/mm2) (P < .001), with a mean loss of 16.9%. A mean IOL tilting of 2.7 ± 0.9 degrees (95% CI: 2.3 to 3 degrees) was found at 60 months postoperatively. The most common postoperative complication were corneal edema in the early course (2 eyes, 7.2%) and localized scleral thinning over the haptic in the late course (9 eyes, 32.1%). At 5 years postoperatively, anterior segment optical coherence tomography showed preserved scleral thickness 199.3 ± 72.7 μm (95% CI: 172.4 to 226.2 μm).

CONCLUSIONS

Sutureless intrascleral fixation of the one-piece IOL demonstrated satisfactory long-term outcomes with good visual acuity and a low rate of complications.

Для цитирования: Vaiano Agostino S, Greco Antonio, Marenco Maria, Garavelli Fabio, De Filippis Alessandro, Deplano Gerardo, Campa Claudio, Parisi Gugliemo, Giannaccare Giuseppe, Reibaldi Michele. Sutureless Scleral Fixation of the Carlevale IOL: A 5-Year Retrospective Study.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2026. DOI: 10.3928/1081597x-20260218-01.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.