A subvalvular catheter approach for radiofrequency ablation of right-sided accessory pathways.

Wieczorek Marcus, Tajtaraghi Sharam, Hoeltgen Reinhard

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Conventional catheter ablation of right-sided accessory pathways (RAPs) can be challenging.

OBJECTIVE

To determine if a subvalvular catheter approach for RAPs targeting the ventricular insertion site, as on the left side, can improve catheter stability and tissue contact and thus increase acute and chronic ablation success rates.

METHODS AND

RESULTS

We retrospectively compared 22 patients (pts) with conventional catheter ablation of RAPs (group 1) with 9 consecutive pts (group 2) undergoing catheter ablation of a RAP using a subvalvular catheter approach targeting the ventricular site of AP. Ablation failed in 2/22 group 1 vs 0/9 group 2 pts (ns) and recurrences of AP conduction were registered in 4/19 group 1 vs 1/9 group 2 pts (ns) during follow-up. Significant shorter values were found in group 2 pts compared with group 1 for number of RF applications (3.6 ± 1.6 vs 8.2 ± 4.3), AP block time (6.2 ± 2.4 vs 9.2 ± 3.9 min), fluoroscopy time (17.2 ± 6.9 vs 25.6 ± 10.3 min), and procedure time (70.8 ± 23.9 vs 138 ± 44.4 min). There were no procedure related complications.

CONCLUSION

Catheter ablation of RAPs using a subvalvular approach seems as effective and safe compared with conventional ablation but with reduced procedure time and radiation exposure and might be at least considered an alternative after failed conventional catheter ablation of RAPs.

Для цитирования: Wieczorek Marcus, Tajtaraghi Sharam, Hoeltgen Reinhard. A subvalvular catheter approach for radiofrequency ablation of right-sided accessory pathways.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2019. DOI: 10.1007/s10840-019-00597-w.