m+Medelevator.RU
← Поиск публикаций
Scandinavian cardiovascular journal : SCJ · 2019

Ventricular electrical delay as a predictor of arrhythmias in patients with cardiac resynchronization implantable cardioverter defibrillator.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Elsaid Ossama, Gulati Vinay, Tecson Kristen, Friedman Meir, Kluger Jeffrey

Аннотация

BACKGROUND: Left ventricular (LV) remodeling and clinical response to cardiac resynchronization therapy (CRT) is inversely related to electrical dyssynchrony, measured as LV lead electrical delay (QLV). Presence of atrial or ventricular arrhythmia is correlated with worsening heart failure and LV remodeling.

OBJECTIVE: We sought to assess the association of QLV with arrhythmic events in CRT recipients.

METHODS: We identified patients implanted with a CRT device at our center. QLV interval was measured and corrected for baseline QRS (cQLV). We performed multivariable Logistic regression to assess the effect of cQLV on the occurrence of atrial/ventricular arrhythmic events.

RESULTS: Sixty-nine patients were included in analyses. The cQLV was significantly shorter in patients with atria tachycardia/supraventricular tachycardia (AT/SVT) events compared to patients without AT/SVT events (43.4 ± 22% vs. 60.3 ± 26.7%, p = .006). In contrast, no significant difference in cQLV was observed between patients with and without ventricular tachycardia/fibrillation (VT/VF) events (46.2 ± 25.4% vs. 56 ± 25.7%, p = .13). cQLV was significantly shorter in patients with new onset AT/SVT events compared to those without (38.3 ± 22.2% vs. 55.7 ± 25.7%, p = .028). In contrast, no significant difference in cQLV was observed between patients with and without new onset VT/VF events (44.2 ± 25.2% vs. 56.3 ± 25.5%, p = .069). Following adjusted analyses, cQLV was a significant predictor of AT/SVT, but not for VT/VF.

CONCLUSION: cQLV is a simple measure that can identify a vulnerable cohort of CRT patients at increased risk for atrial tachyarrhythmias, and hence can predict reverse remodeling and clinical response to CRT treatment.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты