m+Medelevator.RU
← Поиск публикаций
The British journal of surgery · 1991

Intraoperative localization of colorectal cancers using radiolabelled monoclonal antibodies.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Davidson B R, Waddington W A, Short M D, Boulos P B

Аннотация

Radiation detectors may allow the intraoperative localization of small cancer deposits following administration of radiolabelled tumour-associated antibodies. This technique was evaluated in 16 patients with colorectal tumours (14 cancers, one adenoma, one lipoma) with the 111In-labelled monoclonal antibody (MAb) ICR2 which recognizes the tumour-associated epithelial membrane antigen (EMA). At operation counting was carried out (3 x 20 s per site) using a hand-held radiation probe over the primary lesions and any palpable lymph nodes in the mesocolon. The tumour to normal colon (T/NC) ratio of counts recorded at operation was more than 1.5:1 in eight of the 14 patients with cancer (mean(s.d.), 1.54(0.41):1) and 0.91:1 and 1.06:1 respectively in the two patients with benign tumours. Node to normal colon ratios were higher in lymph nodes containing metastases. The uptake of radiolabelled antibody (T/NC ratio) was higher in EMA-expressing cancers than in those not expressing the target antigen (mean(s.d.), 2.45(0.65):1 versus 1.40(0.20):1, P = 0.019). An abdominal tumour model was also developed. Radioactively filled containers of 0.5-10 ml representing tumour deposits were suspended in a tank of 111In solution representing the background activity found in normal tissues. The ratio of radioactivity in the 'tumour' to that of background varied from 2:1 to 8:1. The 'tumour' was considered to be detectable if the mean counts recorded over the 'tumour' exceeded the mean of counts recorded over background by three standard deviations. At a ratio of 2:1 only 'tumours' greater than 5 ml could be detected with a sodium iodide probe and those over 10 ml could be detected with a cadmium telluride (CdTe) probe. At a ratio of 8:1, 'tumours' of 0.5 ml could be detected with either probe. At all ratios and counting periods the NaI probe was more sensitive than the CdTe.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты