MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00535-010-0339-9

Медицинская библиотека · Journal of gastroenterology · 2011

Efficacy of magnifying endoscopy with flexible spectral imaging color enhancement in the diagnosis of colorectal tumors.

Yoshida Naohisa, Naito Yuji, Kugai Munehiro, Inoue Ken, Uchiyama Kazuhiko, Takagi Tomohisa, Ishikawa Takeshi, Handa Osamu, Konishi Hideyuki, Wakabayashi Naoki, Kokura Satoshi, Yagi Nobuaki, Morimoto Yasutaka, Yanagisawa Akio, Yoshikawa Toshikazu

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Magnifying endoscopy with flexible spectral imaging color enhancement (FICE) is an image-enhanced endoscopy that captures the surface and vascular patterns of colorectal tumors. We evaluated and compared FICE magnification to narrow-band imaging (NBI) magnification.

METHODS

Flexible spectral imaging color enhancement or NBI magnification was performed to the visualize surface and vascular patterns of colorectal tumors, classified into 4 types: Type A, Type B, Type C1/C2, and Type C3, as previously reported. A total of 235 colorectal tumors were examined. The correlations between classifications found by FICE or NBI magnification and histopathological diagnoses were examined. Image evaluation was validated by assessing inter-observer and intra-observer agreements on examinations.

RESULTS

Twenty-eight hyperplastic polyps (HPs), 115 tubular adenomas (TAs), 72 mucosal and slightly invaded submucosal cancers (M-sSM), and 20 massively invaded submucosal cancers (mSM) were diagnosed. By FICE magnification, HP and TA were observed in 93.3 and 6.7% of Type A (15 lesions), respectively. TA, M-sSM, and HP were observed in 82.6, 15.4, and 2.0% of Type B (52 lesions),respectively. M-sSM, TA, and mSM were observed in 50.0,46.0, and 4.0% of Type C1/2 (50 lesions), respectively.mSMs were observed in all 7 Type C3 lesions. In diagnosing mSM in Type C3, the sensitivity and specificity of FICE magnification were 77.7 and 100%, respectively, compared to those of NBI, at 63.6 and 99.0%, respectively. Imaging evaluation was validated accurately by intra- and intraobserver measurements showing consistent results.

CONCLUSIONS

The classification of colorectal tumors by FICE magnification correlated well with the histopathological diagnoses, similar to findings for NBI magnification. FICE magnification can be evaluated accurately with the same diagnostic classifications as those used for NBI magnification.

Для цитирования: Yoshida Naohisa, Naito Yuji, Kugai Munehiro, Inoue Ken, Uchiyama Kazuhiko, Takagi Tomohisa, Ishikawa Takeshi, Handa Osamu, Konishi Hideyuki, Wakabayashi Naoki, Kokura Satoshi, Yagi Nobuaki, Morimoto Yasutaka, Yanagisawa Akio, Yoshikawa Toshikazu. Efficacy of magnifying endoscopy with flexible spectral imaging color enhancement in the diagnosis of colorectal tumors.. Journal of gastroenterology. 2011. DOI: 10.1007/s00535-010-0339-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.