Mechanisms by Which Ranolazine Terminates Paroxysmal but Not Persistent Atrial Fibrillation.
Аннотация
BACKGROUND
Ranolazine inhibits Na+ current (INa), but whether it can convert atrial fibrillation (AF) to sinus rhythm remains unclear. We investigated antiarrhythmic mechanisms of ranolazine in sheep models of paroxysmal (PxAF) and persistent AF (PsAF).
METHODS
PxAF was maintained during acute stretch (N=8), and PsAF was induced by long-term atrial tachypacing (N=9). Isolated, Langendorff-perfused sheep hearts were optically mapped.
RESULTS
In PxAF ranolazine (10 μmol/L) reduced dominant frequency from 8.3±0.4 to 6.2±0.5 Hz (P<0.01) before converting to sinus rhythm, decreased singularity point density from 0.070±0.007 to 0.039±0.005 cm-2 s-1 (P<0.001) in left atrial epicardium (LAepi), and prolonged AF cycle length (AFCL); rotor duration, tip trajectory, and variance of AFCL were unaltered. In PsAF, ranolazine reduced dominant frequency (8.3±0.5 to 6.5±0.4 Hz; P<0.01), prolonged AFCL, increased the variance of AFCL, had no effect on singularity point density (0.048±0.011 to 0.042±0.016 cm-2 s-1; P=ns) and failed to convert AF to sinus rhythm. Doubling the ranolazine concentration (20 μmol/L) or supplementing with dofetilide (1 μmol/L) failed to convert PsAF to sinus rhythm. In computer simulations of rotors, reducing INa decreased dominant frequency, increased tip meandering and produced vortex shedding on wave interaction with unexcitable regions.
CONCLUSIONS
PxAF and PsAF respond differently to ranolazine. Cardioversion in the former can be attributed partly to decreased dominant frequency and singularity point density, and prolongation of AFCL. In the latter, increased dispersion of AFCL and likely vortex shedding contributes to rotor formation, compensating for any rotor loss, and may underlie the inefficacy of ranolazine to terminate PsAF.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.