MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2019.07.104

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2019

Clamping versus nonclamping thoracoscopic box ablation in long-standing persistent atrial fibrillation.

Harlaar Niels, Verberkmoes Niels J, van der Voort Pepijn H, Trines Serge A, Verstraeten Stefan E, Mertens Bart J A, Klautz Robert J M, Braun Jerry, van Brakel Thomas J

Сравнительное исследованиеСтатьяVideo-Audio MediaПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare clinical outcomes of clamping devices and linear nonclamping devices for isolation of the posterior left atrium (box) in thoracoscopic ablation of long-standing persistent atrial fibrillation.

METHODS

Eighty patients who underwent thoracoscopic pulmonary vein and box isolation using a bipolar clamping device (42 patients) or bipolar nonclamping device (38 patients) to create the roof/inferior lesions for box isolation were included from 2 centers. Follow-up consisted of 24-hour Holter at regular intervals. Freedom from AF during 1-year follow-up and catheter repeat interventions were compared between groups.

RESULTS

Acute intraoperative electrical isolation of the box compartment was significantly higher in the clamping group than in the nonclamping group (100% and 79%, respectively, P < .01). At 1-year follow-up, 91% of the clamping group and 79% of the nonclamping group were in sinus rhythm. During 1-year follow-up, recurrence rates did not significantly differ between the 2 groups (P = .08). Repeat catheter interventions were required in 10% of the clamping group and 21% of the nonclamping group (P = .15). Conduction gaps in the roof or inferior lesions were found in 1 patient (2%) in the clamping group versus 4 patients (11%) in the nonclamping group (P = .13).

CONCLUSIONS

Thoracoscopic pulmonary vein and box isolation are highly effective in restoring sinus rhythm in long-standing persistent atrial fibrillation on short-term follow-up. Comparison of clamping and nonclamping devices revealed lower rates of intraoperative exit block of the box in the nonclamping group. However, this did not translate into a significant difference in atrial fibrillation freedom at short-term (1-year) follow-up.

Для цитирования: Harlaar Niels, Verberkmoes Niels J, van der Voort Pepijn H, Trines Serge A, Verstraeten Stefan E, Mertens Bart J A, Klautz Robert J M, Braun Jerry, van Brakel Thomas J. Clamping versus nonclamping thoracoscopic box ablation in long-standing persistent atrial fibrillation.. The Journal of thoracic and cardiovascular surgery. 2019. DOI: 10.1016/j.jtcvs.2019.07.104.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.