MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.14023

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2019

Predictors of freedom from atrial arrhythmia recurrence after cryoballoon ablation for persistent atrial fibrillation: A multicenter study.

Reissmann Bruno, Plenge Tobias, Heeger Christian-Hendrik, Schlüter Michael, Wohlmuth Peter, Fink Thomas, Rottner Laura, Tilz Roland Richard, Mathew Shibu, Lemeš Christine, Maurer Tilman, Lüker Jakob, Sultan Arian, Bellmann Barbara, Goldmann Britta, Ouyang Feifan, Kuck Karl-Heinz, Metzner Andreas, Steven Daniel, Rillig Andreas

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: We sought to assess (1) clinical outcomes of second-generation cryoballoon (CB) ablation for persistent atrial fibrillation (AF), and (2) the association of baseline and procedural covariates with atrial arrhythmia recurrence (AAR) after ablation.

METHODS

A total of 135 patients (63 ± 11 years, 96 men [71%]) with persistent AF underwent CB ablation at three experienced electrophysiology centers. Freedom from AAR was estimated with the Kaplan-Meier method. A Cox proportional-hazards model was used to estimate the effects of baseline and procedural covariates on the likelihood of AAR.

RESULTS

Freedom from AAR at 6, 12, and 18 months was estimated at 91% (95% confidence interval [CI] 86%-96%), 75% (95% CI, 67%-83%), and 53% (95% CI, 43%-65%), respectively. The presence of an implantable cardiac device (Hazard ratio [HR] 3.09; 95% CI, 1.37-7.00; P = .007), a left atrial (LA) diameter > 50 mm (HR 1.69; 95% CI, 1.02-2.79; P = .043), and absence of antiarrhythmic drug (AAD) therapy before the ablation procedure (HR 3.12; 95% CI, 1.72-5.64; P < .001) were associated with AAR. A trend toward an increased risk of AAR was revealed for women (HR 1.73; 95% CI, 0.96-3.11; P = .069).

CONCLUSIONS

CB ablation for persistent AF resulted in freedom from AAR about that reported for RF ablation. The presence of an implantable cardiac device, LA size, and absence of AAD therapy at baseline were associated with the risk of AAR.

Для цитирования: Reissmann Bruno, Plenge Tobias, Heeger Christian-Hendrik, Schlüter Michael, Wohlmuth Peter, Fink Thomas, Rottner Laura, Tilz Roland Richard, Mathew Shibu, Lemeš Christine, Maurer Tilman, Lüker Jakob, Sultan Arian, Bellmann Barbara, Goldmann Britta, Ouyang Feifan, Kuck Karl-Heinz, Metzner Andreas, Steven Daniel, Rillig Andreas. Predictors of freedom from atrial arrhythmia recurrence after cryoballoon ablation for persistent atrial fibrillation: A multicenter study.. Journal of cardiovascular electrophysiology. 2019. DOI: 10.1111/jce.14023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.