DOI 10.1136/bmjopen-2018-023775

Медицинская библиотека · BMJ open · 2019

Atrial fibrillation ablation with a spring sensor-irrigated contact force-sensing catheter compared with other ablation catheters: systematic literature review and meta-analysis.

Macle Laurent, Frame Diana, Gache Larry M, Monir George, Pollak Scott J, Boo Lee Ming

СтатьяМетаанализПоддержка исследования: вне правительства СШАСистематический обзорПеревод пока не подготовлен

Аннотация

OBJECTIVES

The objective of our review was to systematically assess available evidence on the effectiveness, safety and efficiency of a spring sensor-irrigated contact force (CF) catheter (THERMOCOOL SMARTTOUCH Catheter (ST)) for percutaneous ablation of paroxysmal or persistent atrial fibrillation (AF), compared with other ablation catheters, or with the ST with the operator blinded to CF data.

DESIGN

Systematic literature review and meta-analysis.

BACKGROUND

Emerging evidence suggests improved clinical outcomes of AF ablation using CF-sensing catheters; however, reviews to date have included data from multiple, distinct CF technologies.

METHODS

We conducted a systematic review and meta-analysis of published studies comparing the use of ST versus other ablation catheters for the treatment of AF. A comprehensive search of electronic and manual sources was conducted. The primary endpoint was freedom from recurrent atrial tachyarrhythmia (AT) at 12 months. Procedural and safety data were also analysed.

RESULTS

Thirty-four studies enrolling 5004 patients were eligible. The use of ST was associated with increased odds of freedom from AT at 12 months (71.0%vs60.8%; OR 1.454, 95% CI 1.12 to 1.88, p=0.004) over the comparator group, and the effect size was most evident in paroxysmal AF patients (75.6%vs64.7%; OR 1.560, 95% CI 1.09 to 2.24, p=0.015). Procedure and fluoroscopy times were shorter with ST (p=0.05 and p<0.01, respectively, vs comparator groups). The reduction in procedure time is estimated at 15.5 min (9.0%), and fluoroscopy time 4.8 min (18.7%). Complication rates, including cardiac tamponade, did not differ between groups.

CONCLUSIONS

Compared with the use of other catheters, AF ablation using the CF-sensing ST catheter for AF is associated with improved success rates, shorter procedure and fluoroscopy times and similar safety profile.

Для цитирования: Macle Laurent, Frame Diana, Gache Larry M, Monir George, Pollak Scott J, Boo Lee Ming. Atrial fibrillation ablation with a spring sensor-irrigated contact force-sensing catheter compared with other ablation catheters: systematic literature review and meta-analysis.. BMJ open. 2019. DOI: 10.1136/bmjopen-2018-023775.