DOI 10.3760/cma.j.issn.0578-1426.2018.08.006
[Changes in renal function after catheter ablation in patients with persistent atrial fibrillation].
Аннотация
Objective
The aim of the study was to evaluate the changes and outcome of kidney function after catheter ablation in patients with persistent atrial fibrillation (PAF).
Methods
A total of 146 patients with PAF underwent primary atrial fibrillation (AF) ablation were enrolled from January 2013 to December 2014 and followed up. The subjects were divided into the AF recurrence and AF non recurrence groups. The estimated glomerular filtration rate (eGFR) was calculated and serum creatinine levels were detected before ablation and during follow-up. Renal failure was defined as ≥ 25% decline in eGFR. Kaplan-Meier survival curves was applied for the incidence of renal failure. Cox proportional hazards models were conducted to assess the relationship between recurrence of AF and renal failure.
Results
After (16.3±11.8) months of follow-up, the eGFR in patients with no recurrence of AF was higher than that in patients with recurrence. eGFR and ΔeGFR in patients with no AF recurrence differed significantly from those in patients with recurrence [(114.15±18.24) ml·min(-1)·1.73m(-2) vs. (98.64±24.09) ml·min(-1)·1.73m(-2), and (7.42±6.36) ml·min(-1)·1.73m(-2) vs. (-11.40±10.19) ml·min(-1)·1.73m(-2), all P<0.001]. The incidence of the renal failure was significantly lower (4.41% vs. 16.67%, P<0.05) and the survival prognosis was significantly better in patients with no recurrence than those in patients with recurrence (χ(2)=5.965, log-rank P=0.05). The multivariate Cox regression analysis revealed that age, baseline eGFR, recurrences of AF and diabetes were independent predictors of the renal failure, with the HR 1.152, 1.086, 13.442 and 6.076, respectively.
Conclusions
PAF patients with no recurrence after ablation had a better renal function than those with recurrence, and the recurrence of AF is associated with the deterioration of kidney function in patients with PAF.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.