MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3760/cma.j.issn.0578-1426.2018.08.006

Медицинская библиотека · Zhonghua nei ke za zhi · 2018

[Changes in renal function after catheter ablation in patients with persistent atrial fibrillation].

Kong Y, Ma C S, Tang R B, Lin J, Cai J F

СтатьяПеревод пока не подготовлен

Аннотация

Objective

The aim of the study was to evaluate the changes and outcome of kidney function after catheter ablation in patients with persistent atrial fibrillation (PAF).

Methods

A total of 146 patients with PAF underwent primary atrial fibrillation (AF) ablation were enrolled from January 2013 to December 2014 and followed up. The subjects were divided into the AF recurrence and AF non recurrence groups. The estimated glomerular filtration rate (eGFR) was calculated and serum creatinine levels were detected before ablation and during follow-up. Renal failure was defined as ≥ 25% decline in eGFR. Kaplan-Meier survival curves was applied for the incidence of renal failure. Cox proportional hazards models were conducted to assess the relationship between recurrence of AF and renal failure.

Results

After (16.3±11.8) months of follow-up, the eGFR in patients with no recurrence of AF was higher than that in patients with recurrence. eGFR and ΔeGFR in patients with no AF recurrence differed significantly from those in patients with recurrence [(114.15±18.24) ml·min(-1)·1.73m(-2) vs. (98.64±24.09) ml·min(-1)·1.73m(-2), and (7.42±6.36) ml·min(-1)·1.73m(-2) vs. (-11.40±10.19) ml·min(-1)·1.73m(-2), all P<0.001]. The incidence of the renal failure was significantly lower (4.41% vs. 16.67%, P<0.05) and the survival prognosis was significantly better in patients with no recurrence than those in patients with recurrence (χ(2)=5.965, log-rank P=0.05). The multivariate Cox regression analysis revealed that age, baseline eGFR, recurrences of AF and diabetes were independent predictors of the renal failure, with the HR 1.152, 1.086, 13.442 and 6.076, respectively.

Conclusions

PAF patients with no recurrence after ablation had a better renal function than those with recurrence, and the recurrence of AF is associated with the deterioration of kidney function in patients with PAF.

Для цитирования: Kong Y, Ma C S, Tang R B, Lin J, Cai J F. [Changes in renal function after catheter ablation in patients with persistent atrial fibrillation].. Zhonghua nei ke za zhi. 2018. DOI: 10.3760/cma.j.issn.0578-1426.2018.08.006.