DOI 10.1016/j.jacep.2017.08.012
Biatrial Electrical and Structural Atrial Changes in Heart Failure: Electroanatomic Mapping in Persistent Atrial Fibrillation in Humans.
Аннотация
OBJECTIVES
This study sought to characterize the biatrial substrate in heart failure (HF) and persistent atrial fibrillation (PeAF).
BACKGROUND
Atrial fibrillation (AF) and HF frequently coexist; however, the contribution of HF to the biatrial substrate in PeAF is unclear.
METHODS
Consecutive patients with PeAF and normal left ventricular (NLV) systolic function (left ventricular ejection fraction [LVEF] >55%) or idiopathic cardiomyopathy (LVEF ≤45%) undergoing AF ablation were enrolled. In AF, pulmonary vein (PV) cycle length (PVCL) was recorded via a multipolar catheter in each PV and in the left atrial appendage for 100 consecutive cycles. After electrical cardioversion, biatrial electroanatomic mapping was performed. Complex electrograms, voltage, scarring, and conduction velocity were assessed.
RESULTS
Forty patients, 20 patients with HF (mean age: 62 ± 8.9 years; AF duration: 15 ± 11 months; LVEF: 33 ± 8.4%) and 20 with NLV (mean age: 59 ± 6.7 years; AF duration: 14 ± 9.1 months; p = 0.69; mean LVEF: 61 ± 3.6%; p < 0.001), were enrolled. HF reduced biatrial tissue voltage (p < 0.001) with greater voltage heterogeneity (p < 0.001). HF was associated with significantly more biatrial fractionation (left atrium [LA]: 30% vs. 9%; p < 0.001; right atrium [RA]: 28% vs. 11%; p < 0.001), low voltage (<0.5 mV) (LA: 23% vs. 6%; p = 0.002; RA: 20% vs 11%; p = 0.006), and scarring (<0.05 mV) in the LA (p = 0.005). HF was associated with a slower average PVCL (185 vs. 164 ms; p = 0.016), which correlated significantly with PV antral bipolar voltage (R = -0.62; p < 0.001) and fractionation (R = 0.46; p = 0.001).
CONCLUSIONS
HF is associated with significantly reduced biatrial tissue voltage, fractionation, and prolongation of PVCL. Advanced biatrial remodeling may have implications for invasive and noninvasive rhythm control strategies in patients with AF and HF.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.