DOI 10.1097/icl.0000000000000791

Медицинская библиотека · Eye & contact lens · 2021

Video Viewing Blink Rate in Normal and Dry Eyes.

Mitchell Travis, Murri Michael, Pflugfelder Stephen C

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Decreased blink rate during video display viewing (VDV) has been reported; however, patients with tear dysfunction often complain of more frequent blinking. The objectives were to compare blink rates during conversation and VDV in normal and dry eyes and correlate blink rates with signs and symptoms.

METHODS

Blink rate was measured with an infrared blink sensor for 2 minutes during conversation and for 2 minutes while watching a video clip (VDV) in patients without dry eye disease (control, n=18) and in patients with tear dysfunction from meibomian gland dysfunction (MGD, n=23), conjunctivochalasis (CCh, n=19), and aqueous tear deficiency (n=34; non-Sjögren syndrome n=18 and Sjögren syndrome n=16). Patients completed visual analogue questionnaires assessing irritation frequency and severity and blink frequency and underwent an ocular surface evaluation. Group comparisons and correlations were calculated.

RESULTS

Compared with control, conversational and VDV blink rates were significantly higher in CCh and aqueous tear deficiency (P≤0.005). Self-reported blink frequency was higher in all tear dysfunction groups compared with control. The VDV blink rate was significantly lower than the conversation blink rate in the control group (P=0.006) but not in any of the tear dysfunction groups. Conversational and VDV blink rates were significantly correlated with irritation frequency and severity.

CONCLUSIONS

Blink rate decreases during VDV in normal eyes; however, this blink rate suppression was not observed in patients with tear dysfunction, perhaps because of their irritation symptoms or tear instability.

Для цитирования: Mitchell Travis, Murri Michael, Pflugfelder Stephen C. Video Viewing Blink Rate in Normal and Dry Eyes.. Eye & contact lens. 2021. DOI: 10.1097/icl.0000000000000791.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.