MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2174/1570161114666160822154351

Медицинская библиотека · Current vascular pharmacology · 2017

Why Not to Use the Handgrip Test in the Assessment of Cardiovascular Autonomic Neuropathy Among Patients with Diabetes Mellitus?

Körei Anna E, Kempler Miklós, Istenes Ildikó, Vági Orsolya E, Putz Zsuzsanna, Horváth Viktor J, Keresztes Katalin, Lengyel Csaba, Tabák Ádám Gy, Spallone Vincenza, Kempler Péter

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Historically, a set of 5 Cardiovascular Autonomic Reflex Tests (CARTs) were considered to be the gold standard in the assessment of Cardiovascular Autonomic Neuropathy (CAN). However, measuring diastolic Blood Pressure (BP) response to sustained handgrip is omitted in recent guidelines. We aimed to assess the association between the handgrip and the other 4 tests as well as to identify determinants of the handgrip test results in diabetic patients.

PATIENTS AND

METHODS

353 patients with diabetes (DM) were recruited (age: 60.2±7.4 years; female: 57.2%; BMI: 29.3±2.1 kg/m2; DM duration: 15.6±9.9 years; HbA1c: 7.8±1.4% (66 mmol/mol); with type 1 DM: 18.1%). CAN was assessed by 5 CARTs: the deep breathing test, Valsalva ratio, 30/15 ratio, handgrip and orthostatic hypotension test.

RESULTS

Sensitivity and specificity of the handgrip test in the diagnosis of definite CAN were 24.6% (95%CI 17.7-33.1%) and 79.4% (95%CI 73.3-84.4%), respectively. Results of the handgrip test did not show any association with those of the deep-breathing test (y=0.004, p=0.563), 30/15 ratio (y=0.282, p=0.357), Valsalva ratio (y=-0.058, p=0.436) and orthostatic hypotension (y=-0.026, p=0.833). Handgrip test abnormality showed an independent association with higher initial diastolic BP (OR 1.05, p=0.0009) and an independent inverse association with the presence of hypertension (OR=0.42, p=0.006).

CONCLUSION

Our data confirm that the handgrip test should no longer be part of the cardiovascular autonomic testing being highly dependent on hypertensive status and baseline diastolic BP. Exaggerated exercise pressor response is proposed as putative mechanism for the inverse association between abnormal results of the handgrip test and hypertension. Adequate CARTs are important to allow their use in clinical trials and for the prevention of DM-associated complications by initiating early treatment.

Для цитирования: Körei Anna E, Kempler Miklós, Istenes Ildikó, Vági Orsolya E, Putz Zsuzsanna, Horváth Viktor J, Keresztes Katalin, Lengyel Csaba, Tabák Ádám Gy, Spallone Vincenza, Kempler Péter. Why Not to Use the Handgrip Test in the Assessment of Cardiovascular Autonomic Neuropathy Among Patients with Diabetes Mellitus?. Current vascular pharmacology. 2017. DOI: 10.2174/1570161114666160822154351.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.