MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1182/bloodadvances.2022008650

Медицинская библиотека · Blood advances · 2023

Mechano-covalent protection of coagulation factor VIII by von Willebrand factor.

Butera Diego, Wang Haoqing Jerry, Woon Heng-Giap, Zhao Yunduo Charles, Ju Lining Arnold, Hogg Philip J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

von Willebrand factor (VWF) is the protective carrier of procoagulant factor VIII (FVIII) in the shear forces of the circulation, prolonging its half-life and delivering it to the developing thrombus. Using force spectroscopy, VWF-FVIII complex formation is characterized by catch-bond behavior in which force first decelerates then accelerates bond dissociation. Patients with mutations in VWF at the FVIII binding site phenocopies hemophilia A and the most common mutations are of cysteine residues involving multiple disulfide bonds. From differential cysteine alkylation and mass spectrometry experiments, 13 VWF disulfide bonds at the FVIII binding site were found to exist in formed and unformed states, and binding of FVIII results in partial formation of 12 of the VWF bonds. Force spectroscopy studies indicate that the VWF-FVIII bond stiffens in response to force and this feature of the interaction is ablated when VWF disulfide bonds are prevented from forming, resulting in slip-only bond behavior. Exposure of VWF to pathological fluid shear forces ex vivo and in vivo causes partial cleavage of all 13 disulfide bonds, further supporting their malleable nature. These findings demonstrate that FVIII binding to VWF involves dynamic changes in the covalent states of several VWF disulfides that are required for productive interaction in physiological shear forces.

Для цитирования: Butera Diego, Wang Haoqing Jerry, Woon Heng-Giap, Zhao Yunduo Charles, Ju Lining Arnold, Hogg Philip J. Mechano-covalent protection of coagulation factor VIII by von Willebrand factor.. Blood advances. 2023. DOI: 10.1182/bloodadvances.2022008650.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.