MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/edm2.66

Медицинская библиотека · Endocrinology, diabetes & metabolism · 2019

Adrenal vein sampling with and without cosyntropin stimulation for detection of surgically remediable aldosteronism.

Violari Elena G, Arici Melih, Singh Charan K, Caetano Celina M, Georgiades Christos S, Grady James, Tendler Beatriz R, Shichman Steven J, Malchoff Carl D

СтатьяПеревод пока не подготовлен

Аннотация

CONTEXT AND

OBJECTIVE

Bilateral adrenal vein sampling (AVS), the diagnostic standard for identifying surgically remediable aldosteronism (SRA), is commonly performed after cosyntropin stimulation (post-ACTHstim). The role of AVS without cosyntropin stimulation (pre-ACTHstim) has not been established. The selectivity index (SI), the adrenal vein (av) serum cortisol concentration divided by that in a peripheral vein, confirms av sampling. The minimally acceptable SI is controversial. The objectives of this study were to determine the role of pre-ACTHstim AVS and a predetermined SI.

DESIGN

Using biochemical cure as the endpoint, we performed a retrospective head-to-head comparison of pre-ACTHstim AVS to post-ACTHstim AVS. The specificity of a predetermined minimum SI of 1.5 in pre-ACTHstim AVS was determined.

PATIENTS: At a regional AVS referral centre, we analysed 32 patients who had undergone simultaneous bilateral AVS both pre- and post-ACTHstim and had returned for postadrenalectomy evaluation.

MEASUREMENTS: Simultaneous bilateral AVS was performed with measurements of venous concentrations of aldosterone and cortisol. End points were postadrenalectomy plasma renin activity, serum aldosterone concentration, and number of antihypertensive medications.

RESULTS

All 32 patients achieved a biochemical cure following adrenalectomy. The two AVS protocols were complementary. Notably, seven patients (22%; CI = 11-38) were found to have SRA by a lateralization index (LI) > 4 on the pre-ACTHstim AVS, but not on the post-ACTHstim AVS. SI pre-ACTHstim was divided into tertiles. Specificity was 100% in all.

CONCLUSIONS

Simultaneous bilateral AVS performed both pre-ACTHstim and post-ACTHstim maximizes SRA identification. A SI of 1.5 pre-ACTHstim does not reduce specificity.

Для цитирования: Violari Elena G, Arici Melih, Singh Charan K, Caetano Celina M, Georgiades Christos S, Grady James, Tendler Beatriz R, Shichman Steven J, Malchoff Carl D. Adrenal vein sampling with and without cosyntropin stimulation for detection of surgically remediable aldosteronism.. Endocrinology, diabetes & metabolism. 2019. DOI: 10.1002/edm2.66.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.