MedElevator Войти в исследования
← Поиск публикаций

DOI 10.14661/2015.1174-1182

Медицинская библиотека · Electronic physician · 2015

Systemic vascular resistance and fluid status in patients with decompensated liver cirrhosis with or without functional renal failure in Egypt.

Barakat Ashraf Abd El-Khalik, Nasr Fatma Mohammad, Metwaly Amna Ahmed, El-Ghannam Maged

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Functional renal failure and cardiovascular dysfunction are common complications of liver cirrhosis. This study aimed to evaluate cardiac performance, systemic vascular resistance (SVR) and fluid status in patients with decompensated liver cirrhosis either with or without functional renal failure.

METHODS

Sixty patients diagnosed as having decompensated liver cirrhosis were divided into two groups. Group 1 included 30 patients with decompensated liver cirrhosis with ascites and with creatinine values ≤ 1.5 mg/dl. Group 2 included 30 azotemic decompensated cirrhotic patients with diagnostic criteria of hepatorenal syndrome (HRS). Also, 20 healthy subjects, of matched age and sex to the Group 1 and Group 2 patients, were included in the study as the control group. All patients and normal controls were subjected to clinical examination, laboratory evaluation, ECG, abdominal ultrasonography and echocardiographic studies.

RESULTS

The echocardiographic and ECG data showed significant increase in LAD (P<0.01, P<0.01), AoD (P<0.05, P<0.01), interventricular septum thickness (IVST) (P<0.01, P<0.01), posterior wall thickness (PWT) (P<0.01, P<0.01), EDD (P<0.01, P<0.01), ESD (P<0.05, P<0.01), left ventricular (LV) mass (P<0.01, P<0.01), and Corrected QT (QTc) (P<0.01, P<0.01) interval with significant decrease in SVR (P<0.01, P<0.01). Additionally, there was significant decrease in IVC diameter in both patients groups compared to the control group (P<0.01, P<0.01).

CONCLUSION

Patients with decompensated liver cirrhosis have low SVR, and Doppler echocardiography provides an easy noninvasive tool to assess this finding. Also, these patients demonstrate small inferior vena cava (IVC) diameter with normal collapsibility, which indicates low effective plasma volume. Measuring IVC diameter and collapsibility are of value in the prediction of intravascular fluid status in liver cirrhosis. This is especially true with renal dysfunction. Early addition of oral vasoconstrictors in decompensated patients may correct the SVR and circulatory dysfunction and hinder HRS occurrence.

Для цитирования: Barakat Ashraf Abd El-Khalik, Nasr Fatma Mohammad, Metwaly Amna Ahmed, El-Ghannam Maged. Systemic vascular resistance and fluid status in patients with decompensated liver cirrhosis with or without functional renal failure in Egypt.. Electronic physician. 2015. DOI: 10.14661/2015.1174-1182.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.