MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0284185113501660

Медицинская библиотека · Acta radiologica (Stockholm, Sweden : 1987) · 2013

Dual-energy CT: clinical application in differentiating an adrenal adenoma from a metastasis.

Shi Jiang Wei, Dai Hong Zhi, Shen Li, Xu Dong Feng

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Application of dual-energy CT in characterization of adrenal nodules has not been well evaluated.

PURPOSE: To evaluate the ability of dual-energy CT scan to differentiate an adrenal adenoma from a metastasis.

MATERIAL AND

METHODS

Fifty-five patients presenting 63 adrenal nodules underwent dual-energy CT scan at tube voltages of 80 kVp and 140 kVp. Mean attenuation values were measured for every nodule at 80/140 kVp and at 40/100 keV. Mean attenuation value changes between 140 kVp and 80 kVp (MAVC140-80kVp) and mean attenuation value changes between 100 keV and 40 keV (MAVC100-40keV) were calculated.

RESULTS

Of the 63 adrenal nodules available for analyses, 42 nodules were classified as adenoma (26 lipid-rich and 16 lipid-poor) and 21 were classified as metastases. MAVC140-80kVp and MAVC100-40keV of all adenomas (including lipid-poor and lipid-rich) were significantly higher than metastases (P < 0.001). According to receiver-operating characteristic (ROC) curve analyses, areas under the ROC curve of MAVC140-80kVp and MAVC100-40keV for diagnosing adrenal adenomas were both of 0.964. When the cut-off points were set at 2.42 HU and 6.95 HU for MAVC140-80kVp and MAVC100-40keV, the two parameters both had a sensitivity of 78.6% and a specificity of 100% in adenoma diagnosis.

CONCLUSION

Unique energy spectrum information provided by dual-energy CT scan displays a high capacity to distinguish adrenal adenoma from metastasis.

Для цитирования: Shi Jiang Wei, Dai Hong Zhi, Shen Li, Xu Dong Feng. Dual-energy CT: clinical application in differentiating an adrenal adenoma from a metastasis.. Acta radiologica (Stockholm, Sweden : 1987). 2013. DOI: 10.1177/0284185113501660.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.