MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1475-097x.2011.01046.x

Медицинская библиотека · Clinical physiology and functional imaging · 2011

Response patterns to bronchodilator and quantitative computed tomography in chronic obstructive pulmonary disease.

Lee Jae Seung, Huh Jin Won, Chae Eun Jin, Seo Joon Beom, Ra Seung Won, Lee Ji-Hyun, Kim Eun-Kyung, Lee Young Kyung, Kim Tae-Hyung, Kim Woo Jin, Lee Jin Hwa, Lee Sang-Min, Lee Sangyeub, Lim Seong Yong, Shin Tae Rim, Yoon Ho Il, Sheen Seung Soo, Oh Yeon-Mok, Lee Sang-Do

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Patients with chronic obstructive pulmonary disease (COPD) show different spirometric response patterns to bronchodilator, such that some patients show improvement principally in expiratory flow (forced expiratory volume in 1 s; FEV(1)), whereas others respond by improvement of lung volume (forced vital capacity; FVC). The mechanisms of these different response patterns to bronchodilator remain unclear. We investigated the associations between bronchodilator responsiveness and quantitative computed tomography (CT) indices in patients with COPD.

METHODS

Data on a total of 101 patients with stable COPD were retrospectively analysed. Volume and flow responses to bronchodilator were assessed by FVC and FEV(1) changes before and after inhalation of salbutamol (400 μg). Volumetric CT was performed to quantify emphysema, air trapping and large airway thickness. Emphysema was assessed by the volume fraction of the lung under -950 Hounsfield units (HU; V(950)) at full inspiration and air trapping by the ratio of mean lung density (MLD) at full expiration and inspiration. Airway wall thickness and wall area percentage (WA%; defined as wall area/[wall area + lumen area] × 100), were measured near the origin of right apical and left apico-posterior bronchus.

RESULTS

Among quantitative CT indices, the CT emphysema index (V(950 insp)) showed a significant negative correlation with postbronchodilator FEV(1) change (R = -0·213, P = 0·004), and the CT air-trapping index correlated positively with postbronchodilator FVC change(R = 0·286, P≤0·001). Multiple linear regression analysis showed that CT emphysema index had independent association with postbronchodilator FEV(1) change and CT air-trapping index with postbronchodilator FVC change.

CONCLUSION

The degrees of emphysema and air trapping may contribute to the different response patterns to bronchodilator in patients with COPD.

Для цитирования: Lee Jae Seung, Huh Jin Won, Chae Eun Jin, Seo Joon Beom, Ra Seung Won, Lee Ji-Hyun, Kim Eun-Kyung, Lee Young Kyung, Kim Tae-Hyung, Kim Woo Jin, Lee Jin Hwa, Lee Sang-Min, Lee Sangyeub, Lim Seong Yong, Shin Tae Rim, Yoon Ho Il, Sheen Seung Soo, Oh Yeon-Mok, Lee Sang-Do. Response patterns to bronchodilator and quantitative computed tomography in chronic obstructive pulmonary disease.. Clinical physiology and functional imaging. 2011. DOI: 10.1111/j.1475-097x.2011.01046.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.