MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1440-1843.2011.02052.x

Медицинская библиотека · Respirology (Carlton, Vic.) · 2012

Airway dimensions and pulmonary function in chronic obstructive pulmonary disease and bronchial asthma.

Kurashima Kazuyoshi, Hoshi Toshiko, Takayanagi Noboru, Takaku Yotaro, Kagiyama Naho, Ohta Chie, Fujimura Masaki, Sugita Yutaka

СтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

COPD and bronchial asthma are chronic airway diseases with a different pathogenesis. Comparisons of differences in airway calibre by bronchial generation between these diseases and their importance to pulmonary function have not been fully studied. We investigated airway calibre and wall thickness in relation to pulmonary function in patients with asthma, COPD, asthma plus emphysema and normal subjects using CT.

METHODS

Sixty-three asthmatic patients, 46 COPD, 23 patients with asthma plus emphysema and 61 control subjects were studied cross-sectionally. We used a software with curved multiplanar reconstruction to measure airway dimensions from 3rd- to 6th-generation bronchi of the right lower posterior bronchus.

RESULTS

Patients with COPD had increased wall thickness, but the airway was not narrow from the 3rd-(subsegmental) to 6th-generation bronchi. Mean bronchial inner diameter (Di) of 3rd- to 6th-generation bronchi in patients with asthma or asthma plus emphysema was smaller than that of COPD patients and normal subjects. Airway luminal area (Ai) of 5th-generation bronchi most closely correlated with pulmonary function in patients with stable asthma. Although Di was similar in patients with asthma and asthma plus emphysema, the Ai of 6th-generation bronchi correlated significantly with pulmonary function in patients with asthma plus emphysema.

CONCLUSIONS

Airway calibre in asthma may be smaller than in COPD. Airflow limitations correlated more closely with peripheral Ai in patients with asthma plus emphysema than in patients with asthma alone.

Для цитирования: Kurashima Kazuyoshi, Hoshi Toshiko, Takayanagi Noboru, Takaku Yotaro, Kagiyama Naho, Ohta Chie, Fujimura Masaki, Sugita Yutaka. Airway dimensions and pulmonary function in chronic obstructive pulmonary disease and bronchial asthma.. Respirology (Carlton, Vic.). 2012. DOI: 10.1111/j.1440-1843.2011.02052.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.