MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/jaha.124.038011

Медицинская библиотека · Journal of the American Heart Association · 2025

Automated Office Blood Pressure Measurements in Waiting Room or Isolated Room for Diagnosis and Phenotyping of Hypertension.

Sánchez Bacaicoa Marisol, Rico Sergio, Gullón Alejandra, Fernandez Pardo Jacinto, Villa Juan, Nadiejda Eva, Robles Roberto, Del Aguila Jose M, Cunha Pedro, Vassilenko Valentina, Rodilla Enrique, Sánchez Muñoz-Torrero Juan F

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Automatic office blood pressure measurement (AOBPM) in the waiting room could improve the performance of diagnosing hypertension without requiring an isolated room to carry out exploration.

METHODS

In a cross-sectional study, we compared the performance to diagnose and phenotyping hypertension by 3 methods of blood pressure measurements, standard office blood pressure, unattended AOBPM in an isolated room or in an office waiting room AOBPM, compared with daytime ambulatory blood pressure measurement (daytime ambulatory blood pressure monitoring) from a 24-hour ambulatory blood pressure monitoring as a reference. The cutoff values for hypertension and validation for waiting room or isolated room AOBPM were performed by receiver operating characteristic curves and Bland-Altman plots compared with daytime ambulatory blood pressure monitoring.

RESULTS

Out of the 548 participants recruited, 349 (64%) had hypertension, while 199 (36%) were being studied for a diagnosis of hypertension. Waiting room AOBPM and unattended AOBPM stratified hypertension status in a comparable way (n=398; 73% [95% CI, 69%-76%; and n=417; 75% [95% CI, 72%-79%] participants, respectively), and both methods stratified better hypertension status than standard office blood pressure measurement did (n=338; 62% [95% CI, 57%-65%]). Overall, the diagnostic accuracy for white coat syndrome was better for waiting room AOBPM, while for masked hypertension it was by unattended AOBPM (80% [95% CI, 77%-83%] versus 87% [95% CI, 83%-89%] and 88% 95% CI, 85%-90%] versus 73% [95% CI, 69%-76%], respectively).

CONCLUSIONS

To assess hypertension status, waiting room AOBPM is equivalent to unattended AOBPM in an isolated room and both better than standard office blood pressure measurement. The detection of hypertension phenotypes differs depending on the site of the measurement, waiting room or isolated room.

REGISTRATION: URL: https://clinicaltrials.gov; unique identifier: NCT06198855.

Для цитирования: Sánchez Bacaicoa Marisol, Rico Sergio, Gullón Alejandra, Fernandez Pardo Jacinto, Villa Juan, Nadiejda Eva, Robles Roberto, Del Aguila Jose M, Cunha Pedro, Vassilenko Valentina, Rodilla Enrique, Sánchez Muñoz-Torrero Juan F. Automated Office Blood Pressure Measurements in Waiting Room or Isolated Room for Diagnosis and Phenotyping of Hypertension.. Journal of the American Heart Association. 2025. DOI: 10.1161/jaha.124.038011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.