MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3174/ajnr.a5423

Медицинская библиотека · AJNR. American journal of neuroradiology · 2017

Semiautomated Evaluation of the Primary Motor Cortex in Patients with Amyotrophic Lateral Sclerosis at 3T.

Donatelli G, Retico A, Caldarazzo Ienco E, Cecchi P, Costagli M, Frosini D, Biagi L, Tosetti M, Siciliano G, Cosottini M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Amyotrophic lateral sclerosis is a neurodegenerative disease involving the upper and lower motor neurons. In amyotrophic lateral sclerosis, pathologic changes in the primary motor cortex include Betz cell depletion and the presence of reactive iron-loaded microglia, detectable on 7T MR images as atrophy and T2*-hypointensity. Our purposes were the following: 1) to investigate the signal hypointensity-to-thickness ratio of the primary motor cortex as a radiologic marker of upper motor neuron involvement in amyotrophic lateral sclerosis with a semiautomated method at 3T, 2) to compare 3T and 7T results, and 3) to evaluate whether semiautomated measurement outperforms visual image assessment.

MATERIALS AND

METHODS

We investigated 27 patients and 13 healthy subjects at 3T, and 19 patients and 18 healthy subjects at 7T, performing a high-resolution 3D multiecho T2*-weighted sequence targeting the primary motor cortex. The signal hypointensity-to-thickness ratio of the primary motor cortex was calculated with a semiautomated method depicting signal intensity profiles of the cortex. Images were also visually classified as "pathologic" or "nonpathologic" based on the primary motor cortex signal intensity and thickness.

RESULTS

The signal hypointensity-to-thickness ratio of the primary motor cortex was greater in patients than in controls (P < .001), and it correlated with upper motor neuron impairment in patients (ρ = 0.57, P < .001). The diagnostic accuracy of the signal hypointensity-to-thickness ratio was high at 3T (area under the curve = 0.89) and even higher at 7T (area under the curve = 0.94). The sensitivity of the semiautomated method (0.81) outperformed the sensitivity of the visual assessment (0.56-0.63) at 3T.

CONCLUSIONS

The signal hypointensity-to-thickness ratio of the primary motor cortex calculated with a semiautomated method is suggested as a radiologic marker of upper motor neuron burden in patients with amyotrophic lateral sclerosis. This semiautomated method may be useful for improving the subjective radiologic evaluation of upper motor neuron pathology in patients suspected of having amyotrophic lateral sclerosis.

Для цитирования: Donatelli G, Retico A, Caldarazzo Ienco E, Cecchi P, Costagli M, Frosini D, Biagi L, Tosetti M, Siciliano G, Cosottini M. Semiautomated Evaluation of the Primary Motor Cortex in Patients with Amyotrophic Lateral Sclerosis at 3T.. AJNR. American journal of neuroradiology. 2017. DOI: 10.3174/ajnr.a5423.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.